Danfoss ETS 400L (034G3711) — electric expansion valve for HVAC-R applications. Maximum working pressure: 37 bar. Compare the reference-specific connections, operating conditions and compatibility below. Send your quantity and delivery destination to AurFort for a quotation.

37 barMax. Working Pressure [bar]
2 5/8 inInlet size [in]
2 5/8 inOutlet size [in]
PRODUCT DATA

Technical specifications

Source: Danfoss product catalog.
Verified September 22, 2026.

034G3711 — selected manufacturer specifications
Gross weight3.423 Kilogram
Net weight2.863 Kilogram
Volume12.899 Liter
EAN5715255223863
TypeETS 400L
Product groupExpansion valves
Product Name DescriptionElectric expansion valve
Ambient temperature range [°C] [max]70 °C
Ambient temperature range [°C] [min]-40 °C
Ambient temperature range [°F] [max]158 °F
Ambient temperature range [°F] [min]-40 °F
ApprovalCE CMIM CRN EAC UA UKCA
Balanced port [Yes/No]Yes
Body materialBrass
Compatible Danfoss controllersAK-XM 208C EKE EKF MCX
Connection materialCopper
Contains batteriesNo
Cv value [gal/min]21.4 gal/min
DirectionStraightway
Electrical conn. Male/FemaleMale
Electrical connectionM12
Electrical connection size4 pin
Enclosure rating IPIP67
Flow characteristicLinear
Flow directionBi-flow
Flow direction indicatorArrow embossed
Fluid Group2
Full travel time CurrDrive [s]12.7 s
Full travel time VoltDrive [s]25.4 s
Inlet connection typeSolder ODF
Inlet size [in]2 5/8 in
Kv value [m³/h]18.5 m³/h
Lubricants compatibilityAB MO PAG PAO POE PVE
Manual operation optionAST-G service driver
Max allowed duty cycle [%]50 %
Max tot PowerCons CurrDrive[W]6.5 W
Max tot PowerCons VoltDrive[W]5.5 W
Max. Working Pressure [bar]37 bar
Max. Working Pressure [psig]536 psig
MaxOPD [bar]26 bar
MaxOPD [psi]377 psi
MaxOPD reverse CurrDrive [bar]10 bar
MaxOPD reverse CurrDrive [psi]145 psi
MaxOPD reverse VoltDrive [bar]10 bar
MaxOPD reverse VoltDrive [psi]145 psi
Motor typeBi-polar
MWP [bar] CRN32 bar
MWP [psig] CRN463 psig
Operating current max. [A]0.5 A
Outlet connection typeSolder ODF
Outlet size [in]2 5/8 in
Packing formatSingle pack
PED categoryI
Phase current (peak) [mA]283 mA
Phase current (RMS) [mA]200 mA
Phase inductance [µH]85000 μH
Product accessoriesStepper valve accessories
Quantity per packing format1 pc
Rated cap. cond. noteFull stroke open, normal flow
Rated cap. conditions [IMP]tcond=90 °F tevap=40 °F tliq=82 °F
Rated cap. conditions [SI]tcond=32 °C tevap=5 °C tliq=28 °C
Rated capacity R1234ze [kW]846 kW
Rated capacity R1234ze [TR]243 TR
Rated capacity R134a [kW]1085 kW
Rated capacity R134a [TR]308 TR
Rated capacity R513A [kW]934 kW
Rated capacity R513A [TR]269 TR
Rated capacity R515B [kW]823 kW
Rated capacity R515B [TR]237 TR
Refrigerant temperature [ºC] [max]140 °C
Refrigerant temperature [ºC] [min]-20 °C
Refrigerant temperature [ºF] [max]284 °F
Refrigerant temperature [ºF] [min]-4 °F
RefrigerantsR1233zd(E) R1234yf R1234ze(E) R134a R22 R245fa R404A R407A R407C R407F R407H R410A R417A R422A R422B R422D R438A R442A R448A R449A R449B R450A R452A R463A R507A R513A R513B R515A R515B
Resistance [kOhm]0.1 kOhm
ServiceableStepper valve spare parts
SightglassYes
Step mode2-phase full step
Total steps3810 (full steps)
UL approved refrigerantsR407F R407H R410A R417A R422A R422B R422D R438A R442A R448A R449A R449B R450A R452A R463A R507A R513A R513B R515A R515B
Voltage [V] DC12 V