SKU 1SBV030177R1302ABB LS31P77L02-S: Limit Switch.
LS31P77L02-SProduct range
Limit SwitchProduct type
1SBV030177R1302Reference
PRODUCT DATA
Technical specifications
Source: ABB English regional product catalog.
Verified September 09, 2026.
| Product ID | 1SBV030177R1302 |
|---|---|
| Catalog Description | LS31P77L02-S Limit Switch |
| Minimum Order Quantity | 10 piece |
| Customs Tariff Number | 85364900 |
| Data Sheet, Technical Information | 1SBC141157C0202 |
| Instructions and Manuals | 1SBC141157C0202 |
| Product Net Width | 30 mm |
| Product Net Height | 175 mm |
| Product Net Depth / Length | 36 mm |
| Product Net Weight | 0.11 kg |
| Action Type of the Contact Element (acc. to IEC 60947-5-1) | Simultaneous Slow Action Contacts |
| Actuation Speed | acc. to IEC 60947-5-1 Max. 0.5 m/s acc. to IEC 60947-5-1 Min. 0.01 m/s |
| Actuation Torque | acc. to IEC 60947-5-1 Min. 0.12 N·m |
| Angular Head Adjustment | adjustable head every 90° |
| Angular Lever Adjustment | 10° in 10° |
| B10d Value | Operations 30 Millions |
| Climatic Withstand | according to IEC 68-2-3 and Salty Mist according to IEC 68-2-11 |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-5-1, Θ = 40 °C 10 A |
| Connecting Capacity | Bar AWG 20 ... AWG 14 mm² Bar 0.5 ... 2.5 mm² |
| Consistency (Measured over 1 Million Operations) | 0.1 mm |
| Contact Element Form | Zb |
| Connecting Terminals (delivered in open position) | M3.5 (+,-) pozidriv 2 screw with cable clamp |
| Degree of Protection | acc. to IEC 60529 IP65 |
| Electrical Shock Protection acc. to IEC 536 | Double insulation - Class II |
| Flammability According to UL94 | V-0 |
| Maximum Electrical Switching Frequency | 3600 cycles per hour (AC-15) 3600 cycles per hour (DC-13) 3600 cycles per hour |
| Mechanical Durability | 0 cycle |
| Mounting by Screws (not supplied) | 2 x M4 Screws |
| Movement to be Detected | angular with lever |
| Number of Auxiliary Contacts NC | 2 |
| Number and Type of Bottom Cable Glands | Pg 11 cable gland |
| Pilot Duty UL/CSA | A600 Q600 |
| Positive Opening Operation Torque (Direct Opening Action) | Minimum Torque acc. to IEC 60947-5-1 0.32 |
| Positive Opening Operation of NC Contact(s) | Yes |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Rated Operational Current AC-15 (Ie) | (230 V AC) 3.1 A (400 V) NC 4 (24 V) 10 A (130 V) 5.5 A (240 V) 3 A |
| Rated Frequency (f) | Supply Circuit 50 / 60 Hz |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 400 V acc. to UL/CSA 600 V |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A (110 V) 0.6 A (125 V) 0.55 A (250 V) 0.4 A |
| Resistance Between Contacts | 25 ms |
| Short-Circuit Protective Devices | gG Type Fuses 10 A |
| Terminal Marking | according to EN 50013 |
| Ambient Air Temperature | Operation -25 ... +70 °C Storage -30 ... +80 °C |
| Resistance to Shock acc. to IEC 60068-2-27 | Half-sine Pulse for 11 ms, No Change in Contact Position 40 m/s² |
| Resistance to Vibrations | No Change in Position of Contacts Greater than 100 µs: 5g 10 ... 500 Hz |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SBD251109E1001 |
| RoHS Declaration | No declaration needed |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006537 |
| Environmental Product Declaration - EPD | No declaration needed |
| CQC Certificate | CQC2004010305127663 |
| cUL Certificate | 9AKK107991A7379 |
| Declaration of Conformity - CCC | 2020980305001785 |
| Declaration of Conformity - CE | 1SBD250883U1000 |
| Declaration of Conformity - UKCA | 1SBD250886U1000 |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 172 mm |
| Package Level 1 Depth / Length | 32 mm |
| Package Level 1 Height | 43 mm |
| Package Level 1 Gross Weight | 0.12 kg |
| Package Level 1 EAN | 3471522617002 |
For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.