AurFort
ABBLS31P80D11-SABB LS31P80D11-S, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

LIMIT SWITCH

LS31P80D11-S

SKU 1SBV030180R1411

ABB LS31P80D11-S: Limit Switch.

LS31P80D11-SProduct range
Limit SwitchProduct type
1SBV030180R1411Reference
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 09, 2026.

1SBV030180R1411 — selected manufacturer specifications
Product ID1SBV030180R1411
Catalog DescriptionLS31P80D11-S Limit Switch
Minimum Order Quantity10 piece
Customs Tariff Number85364900
Data Sheet, Technical Information1SBC141157C0202
Instructions and Manuals1SBC141157C0202
Product Net Width30 mm
Product Net Height90 mm
Product Net Depth / Length30 mm
Product Net Weight0.08 kg
Action Type of the Contact Element (acc. to IEC 60947-5-1)Non-Overlapping Slow Action Contacts
Actuation Speedacc. to IEC 60947-5-1 Max. 0.5 m/s acc. to IEC 60947-5-1 Min. 0.01 m/s
Angular Head Adjustmentadjustable head every 90°
B10d ValueOperations 30 Millions
Climatic Withstandaccording to IEC 68-2-3 and Salty Mist according to IEC 68-2-11
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 10 A
Connecting CapacityBar AWG 20 ... AWG 14 mm² Bar 0.5 ... 2.5 mm²
Consistency (Measured over 1 Million Operations)0.1 mm
Contact Element FormZb
Connecting Terminals (delivered in open position)M3.5 (+,-) pozidriv 2 screw with cable clamp
Degree of Protectionacc. to IEC 60529 IP65
Electrical Shock Protection acc. to IEC 536Double insulation - Class II
Flammability According to UL94V-0
Maximum Electrical Switching Frequency3600 cycles per hour (AC-15) 3600 cycles per hour (DC-13) 3600 cycles per hour
Mechanical Durability0 cycle
Mounting by Screws (not supplied)2 x M4 Screws
Movement to be Detectedsmall latch (key), front or vertical translation
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number and Type of Bottom Cable GlandsPg 11 cable gland
Pilot Duty UL/CSAA600 Q600
Positive Opening Operation Force (Direct Opening Action)Minimum Force acc. to IEC 60947-5-1 30
Positive Opening Operation of NC Contact(s)Yes
Rated Impulse Withstand Voltage (Uimp)6 kV
Rated Operational Current AC-15 (Ie)(230 V AC) 3.1 A (400 V) NC 4 (24 V) 10 A (130 V) 5.5 A (240 V) 3 A
Rated Frequency (f)Supply Circuit 50 / 60 Hz
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 400 V acc. to UL/CSA 600 V
Rated Operational Current DC-13 (Ie)(24 V) 6 A (110 V) 0.6 A (125 V) 0.55 A (250 V) 0.4 A
Resistance Between Contacts25 ms
Short-Circuit Protective DevicesgG Type Fuses 10 A
Terminal Markingaccording to EN 50013
Ambient Air TemperatureOperation -25 ... +70 °C Storage -30 ... +80 °C
Resistance to Shock acc. to IEC 60068-2-27Half-sine Pulse for 11 ms, No Change in Contact Position 10 m/s²
Resistance to VibrationsNo Change in Position of Contacts Greater than 100 µs: 5g 10 ... 500 Hz
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SBD251109E1001
RoHS DeclarationNo declaration needed
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006537
Environmental Product Declaration - EPDNo declaration needed
CQC CertificateCQC2004010305127663
cUL Certificate9AKK107991A7379
Declaration of Conformity - CCC2020980305001785
Declaration of Conformity - CE1SBD250883U1000
Declaration of Conformity - UKCA1SBD250886U1000
Package Level 1 Unitsbox 1 piece
Package Level 1 Width54 mm
Package Level 1 Depth / Length32 mm
Package Level 1 Height95 mm
Package Level 1 Gross Weight0.09 kg
Package Level 1 EAN3471522617057

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.