AurFort
ABBXT1SABB XT1S 160 TMD 160-1600 4p F F InN=100%, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

POWER CIRCUIT-BREAKER FOR TRAFO/GENERATOR/INSTALLATION PROTECTION

XT1S 160 TMD 160-1600 4p F F InN=100%

SKU 1SDA067446R1

ABB XT1S 160 TMD 160-1600 4p F F InN=100%: Power circuit-breaker for trafo/generator/installation protection. Rated current: 160 A. Pole configuration: 4P.

160 ARated current
4PPoles
XT1SProduct range
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 16, 2026.

1SDA067446R1 — selected manufacturer specifications
Product ID1SDA067446R1
Catalog DescriptionXT1S 160 TMD 160-1600 4p F F InN=100%
Country of OriginIndia
Made To OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB015EXPU
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2347
Environmental Product Declaration - EPD9AKK108468A1890 9AKK108468A7793
Extended Product LifetimeProduct is Modular
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
Environmental Information9AKK108467A6707
Order Code US and CanadaXT1SE4160AFF000XXX
E-Number (Norway)4309725
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Product Net Width101.6 mm
Product Net Height130 mm
Product Net Depth / Length70 mm
Product Net Weight1.4 kg
Package Level 1 Unitsbox 1 piece
Package Level 1 Width128 mm
Package Level 1 Height135 mm
Package Level 1 Depth / Length143 mm
Package Level 1 Gross Weight1.504 kg
Package Level 1 EAN8015644013400
Circuit Breaker Type to be AssociatedPower Distribution
Product Main TypeSACE Tmax XT
Product NameMoulded Case Circuit Breaker
Product TypeAutomatic Circuit Breaker
VersionF
CAD Dimensional Drawing1SDH001295R0080
Connecting Capacity Main CircuitBusbar 45.5 ... 80 mm²
Current TypeAC/DC
Electrical Durability120 cycles per hour 8000 cycle
Mechanical Durability240 cycles per hour 25000 cycle
Number of Poles4P
Opening TimeCB with SOR 30 ms CB with UVR 30 ms
Order Multiple1 piece
Power Lossat Rated Operating Conditions per Pole 15 W
Rated Current (In)160 A
Rated Frequency (f)50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)1600 A
Rated Insulation Voltage (Ui)800 V
Rated Operational Voltage690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 80 kA (230 V AC) 80 kA (240 V AC) 80 kA (380 V AC) 50 kA (415 V AC) 37.5 kA (440 V AC) 25 kA (500 V AC) 18 kA (525 V AC) 17.5 kA (690 V AC) 5 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 3 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(220 V AC) 85 kA (230 V AC) 85 kA (240 V AC) 85 kA (380 V AC) 50 kA (415 V AC) 50 kA (440 V AC) 50 kA (500 V AC) 36 kA (525 V AC) 35 kA (690 V AC) 8 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 3 Poles in Series 50 kA
Rated Uninterrupted Current (Iu)160 A
Rated Voltage (Ur)690 V
Recommended Screw DriverMain Circuit M6
ReleaseTMD
Release TypeTM
Setting Range112...160 A
Short-Circuit Performance LevelS
StandardsIEC60947-2
Sub-typeXT1
Terminal Connection TypeFront
Terminal TypeBolt
Tightening Torque6 N·m
ATEX CertificateNo certification needed
Data Sheet, Technical Information1SDC210100D0206 1SDC210099D0206
Declaration of Conformity - CE9AKK106713A5532
GL Certificate1SDL000163R0103
LR Certificate1SDL000163R0100
UL CertificateNo certification needed
VDE CertificateNo certification needed
Dimension Diagram1SDH000719R0100
Mechanical Drawings1SDH000719R0100
Wiring Diagram1SDM000068R0001
Instructions and Manuals1SDH000719R0001

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.