AurFort
ABBXT6SABB XT6S 800 TMA 800-8000 4p F F InN=100%In, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

POWER CIRCUIT-BREAKER FOR TRAFO/GENERATOR/INSTALLATION PROTECTION

XT6S 800 TMA 800-8000 4p F F InN=100%In

SKU 1SDA100753R1

ABB XT6S 800 TMA 800-8000 4p F F InN=100%In: Power circuit-breaker for trafo/generator/installation protection. Rated current: 800 A. Pole configuration: 4P.

800 ARated current
4PPoles
XT6SProduct range
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 16, 2026.

1SDA100753R1 — selected manufacturer specifications
Product ID1SDA100753R1
Catalog DescriptionXT6S 800 TMA 800-8000 4p F F InN=100%In
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2355
Environmental Product Declaration - EPD9AKK108468A9751 9AKK108468A1894
Extended Product LifetimeProduct is Modular
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 60 %
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
Environmental Information9AKK108467A6707
Order Code US and CanadaXT6SE4800BFF000XXX
E-Number (Norway)4380572
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Product Net Width280 mm
Product Net Height268 mm
Product Net Depth / Length103.5 mm
Product Net Weight12 kg
Package Level 1 Unitsbox 1 piece
Package Level 1 Width305 mm
Package Level 1 Height285 mm
Package Level 1 Depth / Length370 mm
Package Level 1 Gross Weight14 kg
Package Level 1 EAN8056221008075
Circuit Breaker Type to be AssociatedPower Distribution
Product Main TypeSACE Tmax XT
Product NameMoulded Case Circuit Breaker
Product TypeAutomatic Circuit Breaker
VersionF
CAD Dimensional Drawing1SDH002065A1214 1SDH002065A1245
Current TypeAC/DC
Electrical Durability5000 cycle 60 cycles per hour
Mechanical Durability20000 cycle 120 cycles per hour
Number of Poles4P
Order Multiple1 piece
Power Loss54.2 W
Rated Current (In)800 A
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)4000…8000 A
Rated Insulation Voltage (Ui)1000 V
Rated Operational Voltage690 V AC 750 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 85 kA (230 V AC) 85 kA (240 V AC) 85 kA (380 V AC) 50 kA (415 V AC) 50 kA (440 V AC) 45 kA (500 V AC) 35 kA (525 V AC) 35 kA (690 V AC) 22 kA (250 V DC) 2 Poles in Series 25 kA (500 V DC) 2 Poles in Series 17.5 kA (750 V DC) 3 Poles in Series 10 kA
Rated Short-time Withstand Current Low Voltage (Icw)10 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(220 V AC) 85 kA (230 V AC) 85 kA (240 V AC) 85 kA (380 V AC) 50 kA (415 V AC) 50 kA (440 V AC) 45 kA (500 V AC) 35 kA (525 V AC) 35 kA (690 V AC) 22 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 2 Poles in Series 35 kA (750 V DC) 3 Poles in Series 24 kA
Rated Uninterrupted Current (Iu)800 A
ReleaseTMA
Release TypeTM
Setting Range560…800 A
Short-Circuit Performance LevelS
StandardsIEC60947-2
Sub-typeXT6
Terminal Connection TypeFront
Data Sheet, Technical Information1SDC210100D0206 1SDC210099D0206
Declaration of Conformity - CE9AKK107680A2825
Mechanical Drawings1SDH002012A1101
Wiring Diagram1SDM000005A1001
Instructions and Manuals1SDH002012A1001