AurFort
ABBPSTX470-600-70ABB PSTX470-600-70, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

SOFT STARTER

PSTX470-600-70

SKU 1SFA898116R7000

ABB PSTX470-600-70: Soft starter.

PSTX470-600-70Product range
Soft starterProduct type
1SFA898116R7000Reference
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 09, 2026.

1SFA898116R7000 — selected manufacturer specifications
Global Commercial AliasPSTX470-600-70
Product ID1SFA898116R7000
ABB Type DesignationPSTX470-600-70
Catalog DescriptionPSTX470-600-70 Softstarter - 470 A - 208 ... 600 V AC
Configuration OnlyNo
Country of OriginSweden China
CriticalityNo
Lead Time0 day 37 day
Made To OrderNo
NoteNo
Product Availability ClassOnly for warranty purposes. Not available for normal sales
Product Sales StatusActive Inactive
Quote OnlyNo
Stocked At WarehousesBRAPR001EXPU CHNOR001EXPU CLABB001EXPU WMSACNURMQ CSB CNIAB001EXPU COABB001EXPU DEAPRMLCEXPU DKSER001EXPU DUABB001EXPU DUABB003EXPU EESER001EXPU EGAUT001EXPU ESATD001EXPU FISER001EXPU FRAUT001EXPU GBINS001EXPU GRABB001EXPU INABB039EXPU INABBRLCEXPU ITIND002EXPU NLABB021EXPU NOATDRLCEXPU SGIND002EXPU TRDMD001EXPU USABB251EXPU ZATAD021EXPU
Storage Location4014
Warranty ReturnProduct under warranty must be returned
Minimum Order Quantity1 piece
Customs Tariff Number85371091
Data Sheet, Technical Information1SFC132012C0201
Instructions and Manuals1SFC132428M0201
Instructions and Manuals (Part 2)1SFC132081M0201
Instructions and Manuals (Part 3)1SFC132060M0201
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC184489_EPLAN
Wiring DiagramN/A
Product Net Width361 mm
Product Net Height493 mm
Product Net Depth / Length282 mm
Product Net Weight25 kg
Rated Operational Voltage208 ... 600 V AC
Rated Control Supply Voltage (Us)100 ... 250 V AC
Rated Control Circuit Voltage (Uc)24 V DC
Rated Frequency (f)50/60 Hz Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe)(230 V) 132 kW (400 V) 250 kW (500 V) 315 kW
Rated Operational Current - In-Line Connection (Ie)470 A
Rated Operational Power - Inside Delta Connectionat 230 V 250 kW at 400 V 450 kW at 500 V 600 kW
Rated Operational Current - Inside Delta Connection814 A
Service Factor Percentage100 %
Overload ProtectionBuilt-in electronic overload protection
Integrated Electronic OverloadYes
Starting Capacity at Maximum Rated Current Ie4xIe for 10s
Ramp Time1 ... 120 s
Initial Voltage During Start10 ... 99 %
Step Down Voltage Special Ramp100 ... 10 %
Switch for Inside Delta ConnectionYes
Run Signal RelayYes
By-pass Signal RelayYes
Fault Signal RelayYes
Overload Signal RelayYes
Signal Indication Ready to Start/Standby ON (LED)Green
Signal Indication Running R (LED)Green
Signal Indication Protection (LED)Yellow
Signal Indication Fault (LED)Red
CommunicationModbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeMain Circuit: Bars
Connecting Capacity Main CircuitHole Diameter 8.5 mm
Connecting Capacity Control CircuitRigid 1 x 2.5 mm²
Connecting Capacity Supply CircuitRigid 1 x 2.5
Tightening TorqueMain Circuit 35 N·m
Product Main TypePSTX470
FunctionAuto phase sequence detection Automatic restart Current limit Current limit ramp Dual current limit Dynamic brake Electricity metering Electronic overload Time-to-cool Emergency mode Event log Full voltage start Jog with slow speed, forward and reverse Keypad password Kick start Limp mode with two-phase motor control if one set of thyristors is shorted Motor heating Pre-start function Pump cleaning Real time clock Sequence start Soft start with torque control Soft start with voltage ramp Soft stop with torque control Soft stop with voltage ramp Stand still brake Start reverse (external contactors) Thyristor runtime measurement Torque limit Voltage sags detection
Protection FunctionBypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning DetailsCurrent imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 150 Hp (220 ... 240 V AC) Three Phase 200 Hp (440 ... 480 V AC) Three Phase 400 Hp (550 ... 600 V AC) Three Phase 500 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
Tightening Torque UL/CSAMain Circuit 309.8
Ambient Air TemperatureOperation -25 ... +60 °C Storage -40 ... +70 °C
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2022-006481
RoHS Declaration2CMT2022-006500
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006524
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
ABB EcoSolutions Profile1SFC100125C0367
End Of Life Disassembling Instructions1SFC132453M0201
Environmental Product Declaration - EPD1SFC132447 1SFC132438
Extended Product LifetimeProduct Durability is Enhanced
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 83.6 %
CQC CertificateCN: CQC2015010304806588 / SE: CQC2015010304797766
Declaration of Conformity - CCCCN: 2020980304001094 / SE: 2020980304001859
Declaration of Conformity - CE2CMT005209
DNV CertificateTAE000087N
EU Data Act Compliance Declaration1SFC132498M0201
Package Level 1 Width470 mm
Package Level 1 Depth / Length381 mm
Package Level 1 Height650 mm
Package Level 1 Gross Weight29 kg
Package Level 1 EAN7320500508954
Package Level 1 Unitsbox 1 piece
IDEA Granular Category Code (IGCC)4740 >> Soft starter

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.