AurFort
ABBCP-S.1ABB CP-S.1 24/40.0, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

DC-POWER SUPPLY

CP-S.1 24/40.0

SKU 1SVR320861R1000

ABB CP-S.1 24/40.0: DC-power supply.

CP-S.1Product range
DC-power supplyProduct type
1SVR320861R1000Reference
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 09, 2026.

1SVR320861R1000 — selected manufacturer specifications
Product ID1SVR320861R1000
Catalog DescriptionCP-S.1 24/40.0 Power supply In:110-240VAC/110-250VDC Out:DC 24V/40A
Minimum Order Quantity1 piece
Customs Tariff Number85044095
Data Sheet, Technical Information1SAC200141H0001
Instructions and Manuals1SVC320360M0000
Wiring Diagram9AKK107992A8774
Product Net Width125 mm
Product Net Height129.4 mm
Product Net Depth / Length127 mm
Product Net Weight2.49 kg
Package Level 1 Width178 mm
Package Level 1 Depth / Length168 mm
Package Level 1 Height188 mm
Package Level 1 Gross Weight2.86 kg
Package Level 1 EAN4013614561139
Package Level 1 Unitsbox 1 piece
Package Level 2 Width350 mm
Package Level 2 Depth / Length555 mm
Package Level 2 Height210 mm
Package Level 2 Gross Weight18.5 kg
Package Level 2 Unitscarton 6 piece
FunctionSwitch mode power supply
Number of Phases1-phase
Rated Input Voltage (UIN)110 ... 240 V AC 110 ... 250 V DC
Input Voltage (Uin)99 ... 264 V AC 99 ... 277 V DC
Typical Input Current(115 V AC) 9.5 A (230 V AC) 5 A
Hold-up Time(230 V AC) min. 20 ms
Rated Frequency (f)50 / 60 Hz DC
Rated Frequency Limits45 ... 65 Hz
Characteristic of OutputU/I Characteristic Curve with Power Reserve
Output Power960 W
Rated Output Voltage24 V DC
Output Voltage (Uout)24 V DC 24 ... 28 V DC
Rated Output Current40 A
Output Current40 A
Output Current Maximum (Iout)60 A
Rated Impulse Withstand Voltage (Uimp)Input Circuit / Output Circuit 4 kV Input Circuit / PE 4 kV Input Circuit / Relay Contact 4 kV Output Circuit / PE 0.8 kV Output Circuit 0.8 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 300 V Input Circuit / PE 300 V Input Circuit / Relay Contact 300 V Output Circuit / PE 50 V
Degree of ProtectionHousing IP20 Terminals IP20
Pollution Degree2
Connecting Capacity Input CircuitFlexible with Ferrule 0.5 ... 10.0 mm² Flexible 0.5 ... 10.0 mm² Rigid 0.5 ... 10.0 mm²
Connecting Capacity Output CircuitFlexible with Ferrule 0.5 ... 10 mm² Flexible 0.5 ... 10.0 mm² Rigid 0.5 ... 10.0 mm²
Tightening Torque2.8 N·m Input Circuit 1.47 N·m Output Circuit 1.47 N·m
Wire Stripping LengthAuxiliary Circuit 7 mm Input Circuit 10 mm Output Circuit 10 mm
Recommended Screw DriverPH2 1 x 5.5 Input Circuit / Output Circuit PH2
Minimum Mounting DistanceOther Device Same Type, Horizontal 25 mm Other Device Same Type, Vertical 50 mm
Mounting Position1
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsIEC/EN 61010-1 IEC/EN 61010-2-201 CAN/CSA C22.2 No.61010-1 IEC/EN 61204-3 IEC/EN 61000-6-2 IEC/EN 61000-6-3 IEC/EN 61000-6-4 EN 55032 EN 55011 CAN/CSA C22.2 No.61010-2-201
Connecting Capacity Input Circuit UL/CSAFlexible with Ferrule 20-8 AWG Flexible 20-8 AWG Rigid 20-8 AWG
Connecting Capacity Output Circuit UL/CSAFlexible with Ferrule 20-8 AWG Flexible 20-8 AWG Rigid 20-8 AWG
Tightening Torque UL/CSAInput Circuit 13 in·lb Output Circuit 13 in·lb
Electrostatic Discharge (ESD Immunity) acc. to IEC 61000-4-2Level 4 Air Discharge 15 kV Level 4 Contact Discharge 8 kV
Radiated Electromagnetic Field Immunity acc. to IEC 61000-4-3Level 3 10 V/m
Surge Immunity acc. to IEC 61000-4-5Level 4 Line-to-Ground 4 kV Level 4 Line-to-Line 2 kV
Electromagnetic Compatibility (EMC)Immunity - Class B Emission - Class B
Ambient Air TemperatureOperation -25 ... +70 °C Storage -40 ... +85 °C
Maximum Operating Altitude Permissible5000 m Without Derating 2000 m
Resistance to Damp Heat acc. to IEC 60068-2-30Test Db: 55°C, 2 cycles
Resistance to Shock acc. to IEC 60068-2-2730g 3 shocks 6 ms
Resistance to Vibrations±0.15 mm 10 ... 58 Hz 10 Sweep Cycles Each Axis: 2g 58 ... 150 Hz
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD982001-4501
RoHS Declaration1SVD982001-4401
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP8813066c-d5b7-4c77-a7a3-21675aef727a Germany
Simplified SCIP0499dcb8-d039-4ae0-af28-93e61c8c5a46 Netherlands 0814bc51-d9ed-4538-aba7-c662c0a50724 Germany 140e05d1-0b44-4c38-929b-0f9a823a64ee Poland 184cf0db-6a96-47b6-b74c-a4e5de367fec Czechia 1fe8d86b-a06a-4f43-aa11-e03354fc09fd Germany 2789a533-a6ae-420d-b00f-90ea2d3b0182 Belgium 2794299e-df1e-4923-acc7-5030e3919aac Spain 28492e48-c5cf-40fb-8968-ed8d332f8e21 Norway 2869396b-8ba5-4cd7-b361-15e254a3b60a Finland 301bb389-d362-48cd-8e19-05233544efc5 Sweden 32a555d7-e6f9-4080-803e-2821d0f3b49a Sweden 469e4d47-2a55-4d05-a2b4-fd02c5ef94ce Hungary 51ddeb05-125e-4580-8083-a4f30f746dc9 France 527ebfc2-a851-4eef-9127-fd6c40bb54b9 Belgium 5b4e7758-f927-4eb7-84b8-a46f7d2f1234 Croatia 6bde752d-fa75-45ad-b6c9-5a547c4bb365 Hungary 8b7117d7-a82c-49e5-a11d-984f4617f508 Portugal 8f7b2cc5-3519-4546-bf97-08c0dd74b2f3 Estonia b66c890a-f66e-4cd8-b5f8-533f1063f3cb Greece b706b933-404d-4fc2-b718-58998c0d2e8b Denmark b7706c17-adc5-4a7e-aef4-960d2a035c96 Poland be7abafa-215e-464c-88ab-c5b86f7d2885 Bulgaria cce756a7-68f4-4ea6-8c5e-50bfc0ced45c Germany cd5d2142-9c5f-4416-a11c-3420b8cf0444 Poland d20edd36-46ab-4912-b8d6-9d1483d469f4 Italy da528829-4b26-44dc-8fc6-5570debd7329 Germany fb8d8208-0b11-43b7-8946-73f425122e70 France
Toxic Substances Control Act - TSCA2CMT2023-006535
CB CertificateCB_DE_2-029958-M1
cULus CertificatecULus61010-1_E174460 cULus121201_E523399
Declaration of Conformity - CE1SVD982043-00
DNV CertificateDNV_TAA0000300
SEMI Certificate9AKK108470A0207
E-Number (Finland)2712890
E-Number (Norway)6608904
E-Number (Sweden)5213658

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.