AurFort
Acti9 iDPN VigiSchneider Electric Residual current breaker with overcurrent protection (RCBO), Acti9 iDPNa Vigi, 1P+N, 25A, C curve, 4500A, AC type, 30mA, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

RESIDUAL CURRENT BREAKER WITH OVERCURRENT PROTECTION (RCBO)

Residual current breaker with overcurrent protection (RCBO), Acti9 iDPNa Vigi, 1P+N, 25A, C curve, 4500A, AC type, 30mA

SKU A9D34625

Schneider Electric A9D34625 is a residual current breaker with overcurrent protection (rcbo) in the Acti9 iDPN Vigi range. Key specifications include mounting mode: Clip-on; rated current: 25 A; poles: 1P + N.

Clip-onMounting mode
25 ARated current
1P + NPoles
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 17, 2026.

A9D34625 — selected manufacturer specifications
Product referenceA9D34625
RangeActi9
Product nameActi9 iDPN Vigi
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Device short nameiDPNa Vigi
Device applicationDistribution
Poles description1P + N
Number of protected poles1
Neutral positionLeft
[In] rated current25 A
Network typeAC
Network frequency50 Hz
Trip unit technologyThermal-magnetic
Curve codeC
Earth-leakage sensitivity30 mA
Suitability for isolationYes conforming to EN/IEC 60947-2
Device location in systemOutgoer
[Ue] rated operational voltage230...240 V AC 50 Hz
Magnetic tripping limit5...10 x In
Residual current tripping technologyVoltage independent
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Breaking capacity4500 A Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
[Ics] rated service breaking capacity4500 A 100 % x Icn at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacityIdm 4500 A at 230...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage400 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kV
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
Comb busbar and distribution block compatibilityTop or bottom: YES
Connection pitch9 mm between phase and neutral
9 mm pitches4
Height85 mm
Width36 mm
Depth73 mm
Net weight125 g
ColourWhite
Mechanical durability20000 cycles
Electrical durability10000 cycles
Locking options descriptionPadlocking device
Connections - terminalsSingle terminal top or bottom 1…16 mm² rigid Single terminal top or bottom 1…10 mm² flexible Single terminal top or bottom 1…10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionIntegrated
StandardsEN/IEC 61009-2-1
Product certificationsVDE
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Overvoltage categoryIII conforming to IEC 60364
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.