MINIATURE CIRCUIT-BREAKER

Miniature circuit-breaker, Acti9 C120N, 1P, 80 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)

SKU A9N18357

Schneider Electric A9N18357 is a miniature circuit-breaker in the Acti9 C120 range. Key specifications include rated current: 80 A at 30 °C; poles: 1P; trip curve: C.

80 A at 30 °CRated current
1PPoles
CTrip curve
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 17, 2026.

A9N18357 — selected manufacturer specifications
Product referenceA9N18357
RangeActi9
Product nameActi9 C120
Product or component typeMiniature circuit-breaker
Device short nameC120N
Device applicationDistribution
Poles description1P
Number of protected poles1
[In] rated current80 A at 30 °C
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Breaking capacity3 kA Icu at 380...415 V AC 50/60 Hz IT conforming to EN/IEC 60947-2 20 kA Icu at 130 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12 V DC conforming to EN/IEC 60947-2 15 kA Icu at 125 V DC conforming to EN/IEC 60947-2 10 kA Icu at <= 144 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230/400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Suitability for isolationYes conforming to IEC 60947-2
StandardsEN/IEC 60898-1 EN/IEC 60947-2
Product certificationsEAC
Network frequency50/60 Hz
[Ue] rated operational voltage380...415 V AC 50/60 Hz 125 V DC <= 144 V DC 12 V DC 220...240 V AC 50/60 Hz 230...400 V AC 50/60 Hz 130 V AC 50/60 Hz 12 V AC 50/60 Hz
Magnetic tripping limit5...10 x In
[Ics] rated service breaking capacity15 kA 75 % conforming to EN/IEC 60947-2 - 130 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - 125 V DC 2.25 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - 12 V DC 10 kA 100 % conforming to EN/IEC 60947-2 - <= 144 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 12 V AC 50/60 Hz 7500 A 75 % conforming to EN/IEC 60898-1 - 230/400 V AC 50/60 Hz
Limitation class3 conforming to EN/IEC 60947-2
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2
Contact position indicatorYes
Control typeToggle
Local signallingON/OFF indication
Mounting modeClip-on
Mounting support35 mm symmetrical DIN rail
Comb busbar and distribution block compatibilityYES
9 mm pitches3
Height81 mm
Depth73 mm
Width27 mm
Net weight0.205 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durability5000 cycles conforming to IEC 60947-2
Locking options descriptionHandle sealable with cable diameter 0.7mm in OFF or ON position
Connections - terminalsTunnel type terminals1…50 mm² rigid Tunnel type terminals1.5…35 mm² flexible
Wire stripping length15 mm
Tightening torque3.5 N.m
Earth-leakage protectionWithout
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
Overvoltage categoryIV
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Operating altitude2000 m
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…85 °C