AurFort
Acti9 C120Schneider Electric C120H - circuit breaker - 2P - 100A - C curve, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

MINIATURE CIRCUIT-BREAKER

C120H - circuit breaker - 2P - 100A - C curve

SKU A9N18458

Schneider Electric A9N18458 is a miniature circuit-breaker in the Acti9 C120 range. Key specifications include rated current: 100 A at 30 °C; poles: 2P; trip curve: C.

100 A at 30 °CRated current
2PPoles
CTrip curve
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 18, 2026.

A9N18458 — selected manufacturer specifications
Product referenceA9N18458
RangeActi9
Product nameActi9 C120
Product or component typeMiniature circuit-breaker
Device short nameC120H
Device applicationDistribution
Poles description2P
Number of protected poles2
Neutral positionLeft
[In] rated current100 A at 30 °C
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Breaking capacity15000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-2
StandardsEN/IEC 60898-1 EN/IEC 60947-2
Product certificationsEAC
Network frequency50/60 Hz
[Ue] rated operational voltage380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC 230...400 V AC 50/60 Hz
Magnetic tripping limit5...10 x In
[Ics] rated service breaking capacity7500 A 50 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC
Limitation class3 conforming to EN/IEC 60947-2
[Ui] rated insulation voltage500 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2
Contact position indicatorYes
Control typeToggle
Local signallingON/OFF indication
Mounting modeClip-on
Mounting support35 mm symmetrical DIN rail
Comb busbar and distribution block compatibilityNO
9 mm pitches6
Height81 mm
Depth73 mm
Width54 mm
Net weight0.41 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durability5000 cycles conforming to IEC 60947-2
Locking options descriptionHandle sealable with cable diameter 0.7mm in OFF or ON position
Connections - terminalsTunnel type terminals1…50 mm² rigid Tunnel type terminals1.5…35 mm² flexible
Wire stripping length15 mm
Tightening torque3.5 N.m
Earth-leakage protectionSeparate block
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-2
Overvoltage categoryIV
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Operating altitude2000 m
Ambient air temperature for operation-30…60 °C
Ambient air temperature for storage-40…70 °C

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.