AurFort
Altivar Soft Starter ATS430Schneider Electric Soft starter, Altivar Soft Starter ATS430, 320A, 208 to 600V AC, control supply 110 to 230V AC, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

SOFT STARTER

Soft starter, Altivar Soft Starter ATS430, 320A, 208 to 600V AC, control supply 110 to 230V AC

SKU ATS430C32S6

Schneider Electric ATS430C32S6 is a soft starter in the Altivar Soft Starter ATS430 range. Key specifications include operational current: Normal duty: 320 A in line (at <40 °C); power supply voltage: 208...600 V AC (- 15...10 %); supply phases: 3 phases.

Normal duty: 320 A in line (at <40 °C)Operational current
208...600 V AC (- 15...10 %)Power supply voltage
3 phasesSupply phases
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 06, 2026.

ATS430C32S6 — selected manufacturer specifications
Product referenceATS430C32S6
Range of productAltivar Soft Starter ATS430
Product or component typeSoft starter
Product destinationAsynchronous motors
Product specific applicationStandard industrial machines
Device short nameATS430
Network number of phases3 phases
Utilisation categoryAC-3A AC-53A
Ue power supply voltage208...600 V AC (- 15...10 %)
power supply frequency50...60 Hz - 20...20 %
[Ie] rated operational currentNormal duty: 320 A in line (at <40 °C)
Service factor at Ie100
Torque controlTrue
IP degree of protectionIP00
Motor power kW90 kW at 230 V in line normal duty 160 kW at 400 V in line normal duty 160 kW at 440 V in line normal duty 220 kW at 500 V in line normal duty 220 kW at 525 V in line normal duty
Motor power hp100 hp at 208 V normal duty 125 hp at 230 V normal duty 250 hp at 460 V normal duty 300 hp at 575 V normal duty
Communication port protocolModbus serial RJ45 Modbus serial open style (DO, D1, PE, COM)
Device connectionIn line
Overload current400 % Ie for 13 s
On-load factor50 %
Operating cycles/hour10 cyc/h
[Us] control circuit voltage110...230 V AC 50...60 Hz - 15...10 %
Apparent power70 VA
Integrated motor overload protectionTrue
motor thermal protection classClass 10E
Protection typePhase failure: mains Thermal protection: mains Thermal protection: starter Current overload: motor Motor underload: motor Excessive acceleration time: motor Motor phase loss detection: motor Protection against line phase inversion: mains External thermal protection: motor Short-circuit between motor phase and earth: motor
current limiting %In (5 x Ie maximum)150…700 %
Rated current pwr loss specification320 A
Power loss static current independent19 W
Power loss per device current dependent46 W
Power loss during starting2819 W during starting at 40 °C at 400% In
StandardsEN/IEC 60947-4-2 UL 60947-4-2 IEC 60664-1
Product certificationscULus CE UKCA CCC RCM EAC KC
MarkingCULus CE UKCA CCC RCM EAC KC
[Uc] control circuit voltage24 V DC
Discrete input number4
Discrete input type(STOP) digital input, 4.4 kOhm (RUN) digital input, 4.4 kOhm (DI3) digital input, 4.4 kOhm (DI4) digital input, 4.4 kOhm
Input compatibilitySTOP: digital input level 1 PLC conforming to EN/IEC 61131-2 RUN: digital input level 1 PLC conforming to EN/IEC 61131-2 DI3: digital input level 1 PLC conforming to EN/IEC 61131-2 DI4: digital input level 1 PLC conforming to EN/IEC 61131-2
Discrete input logicDigital input STOP at State 0: 0...< 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Digital input RUN at State 0: 0...< 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Digital input DI3 at State 0: 0...< 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Digital input DI4 at State 0: 0...< 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
Relay output number2
Relay output typeRelay outputs R1A, R1C NO Relay outputs R1B, R1C NC Relay outputs R2A, R2C NO
Minimum switching current100 mA at 12 V DC for relay outputs
Maximum switching currentRelay outputs 2 A / 250 V AC for AC-15 100000 cycles following IEC 60947-5-1 Relay outputs 2 A / 30 V DC for DC-13 150000 cycles following IEC 60947-5-1
Analogue input number1
Analogue input typePTC1 : PTC temperature probe PTC2 : PTC temperature probe
Analogue output number1
Analogue output typeCurrent output AQ1 : 0...20 mA/4...20 mA , impedance< 500 Ohm Voltage output AQ1 : 0...10 V , impedance> 470 Ohm
Connector type1 RJ45 Open style
Physical interface2-wire RS 485 - connector(s): RJ45 2-wire RS 485 - connector(s): open style (DO, D1, PE, COM)
Transmission frameRTU : 1 RJ45 RTU : open style (DO, D1, PE, COM)
Transmission rate4.8…38.4 kbps for Modbus serial RJ45 0.3...115.2 kbps for Modbus serial open style (DO, D1, PE, COM)
Data format8 bits, odd, even or no parity, 1 or 2 bits to stop for Modbus serial RJ45 8 bits, configurable odd, even or no parity for Modbus serial open style (DO, D1, PE, COM)
Number of addresses0…247 for Modbus serial
Method of accessSlave Modbus serial
Type of polarizationNo impedance for Modbus serial
Display screen availableTrue
Operating positionVertical +/- 10 degree
Height443 mm
Width206 mm
Depth261.2 mm
Net weight16.50 kg
internal bypassTrue
Function availableSingle direction Pre-heating Power monitoring Condition monitoring User management Ports and services hardening Security event logging Cybersecure firmware update Small motor test
material declarationTrue
Electromagnetic compatibilityConducted and radiated emissions level A conforming to IEC 60947-4-2 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Voltage/current impulse level 3 conforming to IEC 61000-4-5 Damped oscillating waves level 3 conforming to IEC 61000-4-18 Immunity to conducted disturbances radio-frequency level 3 conforming to IEC 61000-4-6
Pollution degreeLevel 3
[Uimp] rated impulse withstand voltage6 kV
[Ui] rated insulation voltage600 V
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3
Ambient air temperature for operation-25…40 °C (without derating) 40…60 °C (with current derating of 1 % per °C above 40 °C)
Ambient air temperature for storage-40…70 °C
Ambient air transport temperature-40…70 °C
Operating altitude<= 2000 m without derating > 2000...4800 m with current derating 1 % per 100 m above 2000 m
Relative humidity5…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz
Maximum deflection under vibratory load (during storage)1.75 mm at 2...9 Hz
Maximum deflection under vibratory load (during transport)1.75 mm at 2...9 Hz
Maximum acceleration under vibrational stress (during operation)1 gn at 13…200 Hz
Maximum acceleration under vibratory load (during storage)1 gn at 9…200 Hz 1.5 gn at 200…500 Hz
Maximum acceleration under vibratory load (during transport)1 gn at 9…200 Hz 1.5 gn at 200…500 Hz
Maximum acceleration under shock impact (during operation)15 gn at 11 ms
Maximum acceleration under shock load (during storage)10 gn at 11 ms
Maximum acceleration under shock load (during transport)10 gn at 11 ms

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.