AurFort
Altivar Machine ATV320Schneider Electric variable speed drive, Altivar Machine ATV320, 4kW, 380 to 500V, 3 phases, book, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

VARIABLE SPEED DRIVE

variable speed drive, Altivar Machine ATV320, 4kW, 380 to 500V, 3 phases, book

SKU ATV320U40N4B

Schneider Electric ATV320U40N4B is a variable speed drive in the Altivar Machine ATV320 range. Key specifications include motor power: 4.0 kW for heavy duty; supply voltage: 380...500 V - 15...10 %; ip protection: IP20.

4.0 kW for heavy dutyMotor power
380...500 V - 15...10 %Supply voltage
IP20IP protection
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 17, 2026.

ATV320U40N4B — selected manufacturer specifications
Product referenceATV320U40N4B
Range of productAltivar Machine ATV320
Product or component typeVariable speed drive
Product specific applicationComplex machines
VariantStandard version
Format of the driveBook
Mounting modeCabinet mount
Communication port protocolModbus serial CANopen
Option cardCommunication module, CANopen Communication module, EtherCAT Communication module, Profibus DP V1 Communication module, PROFINET Communication module, Ethernet Powerlink Communication module, EtherNet/IP Communication module, DeviceNet
[Us] rated supply voltage380...500 V - 15...10 %
nominal output current9.5 A
Motor power kW4.0 kW for heavy duty
Motor power hp5 hp
EMC filterClass C2 EMC filter integrated
IP degree of protectionIP20
Discrete input number7
Discrete input typeSTO safe torque off, 24 V DC, impedance: 1.5 kOhm DI1...DI6 logic inputs, 24 V DC (30 V) DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
Discrete input logicPositive logic (source) Negative logic (sink)
Discrete output number3
Discrete output typeOpen collector DQ+ 0…1 kHz 30 V DC 100 mA Open collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input number3
Analogue input typeAI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
Analogue output number1
Analogue output typeSoftware-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bits Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Relay output typeConfigurable relay logic R1A 1 NO electrical durability 100000 cycles Configurable relay logic R1B 1 NC electrical durability 100000 cycles Configurable relay logic R1C Configurable relay logic R2A 1 NO electrical durability 100000 cycles Configurable relay logic R2C
Maximum switching currentRelay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC
Minimum switching currentRelay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
Method of accessSlave CANopen
4 quadrant operation possibleTrue
Asynchronous motor control profileVoltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points
Synchronous motor control profileVector control without sensor
Maximum output frequency0.599 kHz
Acceleration and deceleration rampsLinear U S CUS Ramp switching Acceleration/deceleration ramp adaptation Acceleration/deceleration automatic stop with DC injection
Motor slip compensationAutomatic whatever the load Adjustable 0...300 % Not available in voltage/frequency ratio (2 or 5 points)
Switching frequency2...16 kHz adjustable 4...16 kHz with derating factor
Nominal switching frequency4 kHz
Braking to standstillBy DC injection
Brake chopper integratedTrue
Line current13.7 A at 380 V (heavy duty) 10.5 A at 500 V (heavy duty)
Maximum input current13.7 A
Maximum output voltage500 V
Apparent power9.1 kVA at 500 V (heavy duty)
Network frequency50...60 Hz
Relative symmetric network frequency tolerance5 %
Prospective line Isc5 kA
Base load current at high overload9.5 A
Power dissipation in WFan: 111 W at 380 V, switching frequency 4 kHz
With safety function Safely Limited Speed (SLS)True
With safety function Safe brake management (SBC/SBT)False
With safety function Safe Operating Stop (SOS)False
With safety function Safe Position (SP)False
With safety function Safe programmable logicFalse
With safety function Safe Speed Monitor (SSM)False
With safety function Safe Stop 1 (SS1)True
With sft fct Safe Stop 2 (SS2)False
With safety function Safe torque off (STO)True
With safety function Safely Limited Position (SLP)False
With safety function Safe Direction (SDI)False
Protection typeInput phase breaks: drive Overcurrent between output phases and earth: drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: drive
Width60 mm
Height325.0 mm
Depth245.0 mm
Net weight3.0 kg
Transient overtorque170…200 % of nominal motor torque
Operating positionVertical +/- 10 degree
Product certificationsCE ATEX NOM GOST EAC RCM KC
MarkingCE ATEX UL CSA EAC RCM
StandardsIEC 61800-5-1
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz
Permitted relative humidity (during operation)Class 3K5 according to EN 60721-3
Volume of cooling air11.3 m3/h
Overvoltage categoryIII
Regulation loopAdjustable PID regulator
Speed accuracy+/- 10 % of nominal slip 0.2 Tn to Tn
Pollution degree2
Ambient air transport temperature-25…70 °C
Ambient air temperature for operation-10…50 °C without derating 50…60 °C with derating factor
Ambient air temperature for storage-25…70 °C

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.