AurFort
Altivar Process ATV600Schneider Electric variable speed drive, Altivar Process ATV600, ATV630, 11kW, 15hp, 380 to 480V, IP21, UL type 1, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

VARIABLE SPEED DRIVE

variable speed drive, Altivar Process ATV600, ATV630, 11kW, 15hp, 380 to 480V, IP21, UL type 1

SKU ATV630D11N4

Schneider Electric ATV630D11N4 is a variable speed drive in the Altivar Process ATV600 range. Key specifications include motor power: 11 kW (normal duty); supply voltage: 380...480 V; supply phases: 3 phases.

11 kW (normal duty)Motor power
380...480 VSupply voltage
3 phasesSupply phases
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 06, 2026.

ATV630D11N4 — selected manufacturer specifications
Product referenceATV630D11N4
Range of productAltivar Process ATV600
Product specific applicationProcess and utilities
Product or component typeVariable speed drive
VariantStandard version
Device short nameATV630
Mounting modeWall mount
Communication port protocolModbus TCP Ethernet Modbus serial
[Us] rated supply voltage380...480 V
Relative symmetric mains voltage tolerance10 %
Relative symmetric network frequency tolerance5 %
nominal output current23.5 A
IP degree of protectionIP21 conforming to IEC 61800-5-1 IP21 conforming to IEC 60529
Product destinationAsynchronous motors Synchronous motors
EMC filterIntegrated with 50 m conforming to IEC 61800-3 category C2 Integrated with 150 m conforming to IEC 61800-3 category C3
Degree of protectionUL type 1 conforming to UL 508C
Type of coolingForced convection
Supply frequency50...60 Hz - 5...5 %
Motor power kW11 kW (normal duty) 7.5 kW (heavy duty)
Motor power hp15 hp normal duty 10 hp heavy duty
Line current19.8 A at 380 V (normal duty) 17 A at 480 V (normal duty) 14.1 A at 380 V (heavy duty) 12.5 A at 480 V (heavy duty)
Continuous output current23.5 A at 4 kHz for normal duty 16.5 A at 4 kHz for heavy duty
Speed drive output frequency0.1…500 Hz
Safety functionSTO (safe torque off) SIL 3
Option cardSlot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink
Discrete input number8
Discrete input typeDI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Discrete input logicPositive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1) Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1)
Discrete output number0
Discrete output typeRelay outputs R1A, R1B, R1C 250 V AC 3000 mA Relay outputs R1A, R1B, R1C 30 V DC 3000 mA Relay outputs R2A, R2C 250 V AC 5000 mA Relay outputs R2A, R2C 30 V DC 5000 mA Relay outputs R3A, R3C 250 V AC 5000 mA Relay outputs R3A, R3C 30 V DC 5000 mA
Analogue input number3
Analogue input typeAI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits AI2 voltage analog input: - 10...10 V DC, impedance: 31.5 kOhm, resolution 12 bits
Analogue output number2
Analogue output typeSoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits Software-configurable current DQ-, DQ+: 30 V DC Software-configurable current DQ-, DQ+: 100 mA
Relay output number3
Relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
Network number of phases3 phases
Physical interfaceEthernet 2-wire RS 485
Method of accessSlave Modbus TCP
Transmission rate10, 100 Mbits 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Transmission frameRTU
Output voltage<= power supply voltage
Permissible temporary current boost1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty)
Data format8 bits, configurable odd, even or no parity
Type of polarizationNo impedance
Frequency resolutionDisplay unit: 0.1 Hz Analog input: 0.012/50 Hz
Electrical connectionControl: removable screw terminals 0.5...1.5 mm²/20 AWG...16 AWG Motor: screw terminal 6...10 mm²/10 AWG...8 AWG Line side: screw terminal 6 mm²/10 AWG
Connector typeRJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP RJ45 (on the remote graphic terminal) for Modbus serial
Exchange modeHalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Number of addresses1…247 for Modbus serial
SupplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Local signalling3 LEDs for local diagnostic 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
Input compatibilityDI1...DI6: discrete input level 1 PLC conforming to IEC 61131-2 DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2
Sampling duration2 ms +/- 0.5 ms (DI1...DI4) - discrete input 5 ms +/- 1 ms (DI5, DI6) - discrete input 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input 10 ms +/- 1 ms (AO1) - analog output
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AO1, AO2: +/- 0.2 % for analog output
Refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
IsolationBetween power and control terminals
Discrete and process manufacturingBuilding - HVAC compressor centrifugal Food and beverage processing other application Mining mineral and metal fan Mining mineral and metal pump Oil and gas fan Water and waste water other application Building - HVAC screw compressor Food and beverage processing pump Food and beverage processing fan Food and beverage processing atomization Oil and gas electro submersible pump (ESP) Oil and gas water injection pump Oil and gas jet fuel pump Oil and gas compressor for refinery Water and waste water centrifuge pump Water and waste water positive displacement pump Water and waste water electro submersible pump (ESP) Water and waste water screw pump Water and waste water lobe compressor Water and waste water screw compressor Water and waste water compressor centrifugal Water and waste water fan Water and waste water conveyor Water and waste water mixer
Power range7…11 kW at 380…440 V 3 phases 7…11 kW at 480…500 V 3 phases
Enclosure mountingWall mounted
4 quadrant operation possibleFalse
Asynchronous motor control profileConstant torque standard Optimized torque mode Variable torque standard
Synchronous motor control profilePermanent magnet motor Synchronous reluctance motor
Maximum output frequency500 kHz
Acceleration and deceleration rampsLinear adjustable separately from 0.01...9999 s
Motor slip compensationAdjustable Can be suppressed Not available in permanent magnet motor law Automatic whatever the load
Switching frequency2...12 kHz adjustable 4...12 kHz with derating factor
Nominal switching frequency4 kHz
Braking to standstillBy DC injection
Brake chopper integratedFalse
Maximum input current19.8 A
Maximum output voltage480.0 V
Apparent power14.1 kVA at 480 V (normal duty) 10.4 kVA at 480 V (heavy duty)
Maximum transient current25.9 A during 60 s (normal duty) 24.8 A during 60 s (heavy duty)
Network frequency50...60 Hz
Prospective line Isc50 kA
Base load current at high overload16.5 A
Base load current at low overload23.5 A
Power dissipation in WNatural convection: 51 W at 380 V, switching frequency 4 kHz Forced convection: 255 W at 380 V, switching frequency 4 kHz
With safety function Safely Limited Speed (SLS)False
With safety function Safe brake management (SBC/SBT)False
With safety function Safe Operating Stop (SOS)False
With safety function Safe Position (SP)False
With safety function Safe programmable logicFalse
With safety function Safe Speed Monitor (SSM)False
With safety function Safe Stop 1 (SS1)False
With sft fct Safe Stop 2 (SS2)False
With safety function Safe torque off (STO)True
With safety function Safely Limited Position (SLP)False
With safety function Safe Direction (SDI)False
Protection typeThermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
Quantity per set1
Width171 mm
Height409 mm
Depth233 mm
Net weight7.7 kg
Insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
Noise level56 dB
Pollution degree2
Vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation-15…50 °C (without derating) 50…60 °C (with derating factor)
Operating altitude<= 1000 m without derating 1000...4800 m with current derating 1 % per 100 m
Operating positionVertical +/- 10 degree
Product certificationsATEX INERIS CSA UL ATEX zone 2/22 DNV-GL TÜV
MarkingCE
StandardsUL 508C IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
Maximum THDI<48 % from 80...100 % of load conforming to IEC 61000-3-12
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Environmental class (during operation)Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)10 m/s² at 13...200 Hz
Maximum deflection under vibratory load (during operation)1.5 mm at 2...13 Hz
Permitted relative humidity (during operation)Class 3K5 according to EN 60721-3
Volume of cooling air103 m3/h
Overvoltage categoryIII
Regulation loopAdjustable PID regulator
Ambient air transport temperature-40…70 °C
Ambient air temperature for storage-40…70 °C

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.