ComPacT NSX100...250Schneider Electric trip unit MicroLogic 2.2 M for ComPacT NSX 160/250 circuit breakers, electronic, rating 150 A, 3 poles 3d, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

TRIP UNIT

trip unit MicroLogic 2.2 M for ComPacT NSX 160/250 circuit breakers, electronic, rating 150 A, 3 poles 3d

SKU C1632M150

Schneider Electric C1632M150 is a trip unit in the ComPacT NSX100...250 range. Key specifications include poles: 3P; trip unit: MicroLogic 2.2 M; operational voltage: 690 V AC 50/60 Hz.

3PPoles
MicroLogic 2.2 MTrip unit
690 V AC 50/60 HzOperational voltage
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 06, 2026.

C1632M150 — selected manufacturer specifications
Product referenceC1632M150
RangeComPacT
Range of productComPacT NSX100...250
Product or component typeTrip unit
Trip unit nameMicroLogic 2.2 M
Trip unit technologyElectronic
Range compatibilityComPacT NSX160 ComPacT NSX250
Device applicationMotor
Poles description3P
Protected poles description3D
Trip unit protection functionsLSoI
Protection typeL : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection
Trip unit rating150 A at 65 °C
[Ue] rated operational voltage690 V AC 50/60 Hz
Network typeAC
Network frequency50/60 Hz
Circuit breaker mounting modeFixed
Motor tripping class10 5 20
Complementary motor protectionPhase unbalance
Long-time pick-up adjustment type Ir (thermal protection)Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range70...150 A
Long-time protection delay adjustment type trFixed
[tr] long-time protection delay adjustment range120 s at 1.5 x Ir for trip class 5 6.5 s at 6 x Ir for trip class 5 5 s at 7.2 x Ir for trip class 5 240 s at 1.5 x Ir for trip class 10 13.5 s at 6 x Ir for trip class 10 10 s at 7.2 x Ir for trip class 10 480 s at 1.5 x Ir for trip class 20 26 s at 6 x Ir for trip class 20 20 s at 7.2 x Ir for trip class 20
Thermal memory20 minutes before and after tripping
Short-time protection pick-up adjustment type IsdAdjustable 9 settings
[Isd] Short-time protection pick-up adjustment range5...13 x Ir
Short-time protection delay adjustment type tsdFixed
Instantaneous protection pick-up adjustment type IiFixed
[Ii] instantaneous protection pick-up adjustment range2250 A
Earth-leakage protectionWithout
Zone selective interlocking ZSIWithout
Local signallingFlashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point
StandardsEN/IEC 60947-2
Electrical shock protection classClass II
Pollution degree3 conforming to IEC 60947-1
IP degree of protectionIP40 conforming to IEC 60529
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.