Official EasyPact NW2 family illustration from Schneider Electric’s English catalog. The pictured configuration may differ from this fixed 3-pole reference.
AIR CIRCUIT BREAKER
EasyPact NW2 H air circuit breaker, 1250 A, 3P, fixed, manual, TS 5.0S
SKU ENW212H3MF5SHA 3-pole EasyPact NW2 H air circuit breaker rated at 1250 A, with fixed mounting and manual operation. Its TS 5.0S trip system provides long-time, short-time and instantaneous protection. Ultimate breaking capacity is 66 kA at 220–440 V AC.
1250 ARated current
3PPoles
66 kAIcu at 220–440 V AC
PRODUCT DATA
Technical specifications
Source: Schneider Electric English EasyPact NW catalog, LVED250101EN.
Verified September 06, 2026.
| Product reference | ENW212H3MF5SH |
|---|---|
| Product range | EasyPact NW2 |
| Product type | Air circuit breaker |
| Rated current In | 1250 A at 40 °C |
| Number of poles | 3P |
| Performance level | H |
| Mounting | Fixed |
| Operating mechanism | Manual |
| Connection configuration | HH — horizontal rear connections |
| Trip system | TS 5.0S (TSS Standard) |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Long-time current setting Ir | 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 0.95, 0.98 or 1 × In; off setting available |
| Rated operational voltage Ue | 690 V AC, 50/60 Hz |
| Rated insulation voltage Ui | 1000 V |
| Rated impulse withstand voltage Uimp | 12 kV |
| Ultimate breaking capacity Icu | 66 kA at 220–440 V AC 50 kA at 690 V AC |
| Service breaking capacity Ics | 100% of Icu |
| Short-time withstand current Icw | 66 kA for 1 s at 220–440 V AC 50 kA for 1 s at 690 V AC 50 kA for 3 s at 440/690 V AC |
| Making capacity Icm | 145 kA peak at 220–440 V AC 105 kA peak at 690 V AC |
| Utilisation category | B |
| Standard | IEC 60947-2 |
| Suitability for isolation | Yes, IEC 60947-2 |
| Pollution degree | 4, IEC 60664-1 |
| Mechanical life without maintenance | 10000 opening/closing cycles |
| Mechanical life with maintenance | 20000 opening/closing cycles |
| Electrical life without maintenance | 8000 opening/closing cycles at 440 V 4000 opening/closing cycles at 690 V |
| Rating conditions | Icu, Ics, Icw and Icm values apply with rear termination. |
| Manufacturer source sections | LVED250101EN, April 2026: A-6–A-7 (ratings); A-12–A-13 (trip system); F-12 (exact ordering references). |
| Dimensions (H × W × D), fixed 3P | 352 × 422 × 297 mm |
| Approximate weight, fixed 3P | 40 kg |
For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.