AurFort
EasyPact NW2Schneider Electric EasyPact NW2 H air circuit breaker, 4000 A, 4P, fixed, manual, TS 5.0S, manufacturer catalog image

Official EasyPact NW2 family illustration from Schneider Electric’s English catalog. The pictured configuration may differ from this fixed 4-pole reference.

AIR CIRCUIT BREAKER

EasyPact NW2 H air circuit breaker, 4000 A, 4P, fixed, manual, TS 5.0S

SKU ENW240H4MF5SH

A 4-pole EasyPact NW2 H air circuit breaker rated at 4000 A, with fixed mounting and manual operation. Its TS 5.0S trip system provides long-time, short-time and instantaneous protection. Ultimate breaking capacity is 66 kA at 220–440 V AC.

4000 ARated current
4PPoles
66 kAIcu at 220–440 V AC
PRODUCT DATA

Technical specifications

Source: Schneider Electric English EasyPact NW catalog, LVED250101EN.
Verified September 06, 2026.

ENW240H4MF5SH — selected manufacturer specifications
Product referenceENW240H4MF5SH
Product rangeEasyPact NW2
Product typeAir circuit breaker
Rated current In4000 A at 40 °C
Number of poles4P
Performance levelH
MountingFixed
Operating mechanismManual
Connection configurationHH — horizontal rear connections
Trip systemTS 5.0S (TSS Standard)
Protection functionsLong-time, short-time and instantaneous (LSI)
Long-time current setting Ir0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 0.95, 0.98 or 1 × In; off setting available
Rated operational voltage Ue690 V AC, 50/60 Hz
Rated insulation voltage Ui1000 V
Rated impulse withstand voltage Uimp12 kV
Ultimate breaking capacity Icu66 kA at 220–440 V AC 50 kA at 690 V AC
Service breaking capacity Ics100% of Icu
Short-time withstand current Icw66 kA for 1 s at 220–440 V AC 50 kA for 1 s at 690 V AC 50 kA for 3 s at 440/690 V AC
Making capacity Icm145 kA peak at 220–440 V AC 105 kA peak at 690 V AC
Utilisation categoryB
StandardIEC 60947-2
Suitability for isolationYes, IEC 60947-2
Pollution degree4, IEC 60664-1
Mechanical life without maintenance10000 opening/closing cycles
Mechanical life with maintenance20000 opening/closing cycles
Electrical life without maintenance5000 opening/closing cycles at 440 V 2500 opening/closing cycles at 690 V
Rating conditionsIcu, Ics, Icw and Icm values apply with rear termination.
Manufacturer source sectionsLVED250101EN, April 2026: A-6–A-7 (ratings); A-12–A-13 (trip system); F-12 (exact ordering references).
Fourth-pole rating4000 A
Dimensions (H × W × D), fixed 4P352 × 537 × 297 mm
Approximate weight, fixed 4P80 kg

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.