AurFort
EasyLogic DM6X00H NCSchneider Electric EASYLOGIC DM6200H VAF PF DPM NONC CL1.0, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

VAF PF METER

EASYLOGIC DM6200H VAF PF DPM NONC CL1.0

SKU METSEDM6000HCL10NC

Schneider Electric METSEDM6000HCL10NC is a vaf pf meter in the EasyLogic DM6X00H NC range. Key specifications include device short name: DM6000H; supply voltage: 48...277 V AC 45...65 Hz; communication port protocol: -.

DM6000HDevice short name
48...277 V AC 45...65 HzSupply voltage
-Communication port protocol
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 17, 2026.

METSEDM6000HCL10NC — selected manufacturer specifications
Product referenceMETSEDM6000HCL10NC
RangeEasyLogic
Product nameEasyLogic DM6X00H NC
Device short nameDM6000H
Product or component typeVAF PF meter
Device applicationRemote monitoring
Type of measurementCurrent Voltage Frequency RPM
Metering typeUnbalance current Calculated neutral current Unbalance voltage Rotation speed Phase currents Voltage U21, U32, U13, V1, V2, V3 Frequency Average voltage Vavg Average current Iavg
Counter functionsPower interruption ON hour counting
[Us] rated supply voltage48...277 V AC 45...65 Hz 48...277 V DC
Network frequency50 Hz 60 Hz
[In] rated current1 A 5 A
type of network2P + N 2P 3P + N 3P 1P + N
Maximum power consumption in VA4 VA at 240 V between phase and neutral
Maximum power consumption in W2 W at 240 V
Display type8 segments LED
Display colourRed
Messages display capacity3 fields of 4 characters
Display digits12 digit(s) - 14.2 mm in height
Communication of dataReading of measurements Instantaneous and demand values Revolution speed All counters
Tamperproof of settingsProtected by access code
Sampling rate32 samples/cycle
Measurement current5…6000 mA
SignalCurrent 0.005...10 A (impedance 0.3 MOhm)6 x
Measurement voltage35…480 V AC 50...60 Hz between phases 46…277 V AC 50...60 Hz between phase and neutral 277…999000 V AC 50...60 Hz with external VT
Frequency measurement range45…65 Hz
Measurement accuracyFrequency +/- 0.05 % Power factor +/- 0.01 Current +/- 1 % Voltage +/- 1 %
Accuracy classClass 1
Demand intervals1 s
Local signallingGreen LED: activity Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh)
Communication port protocol-
MaterialPolycarbonate
Flame retardanceV-0 conforming to UL 94
Mounting modeFlush-mounted
Mounting supportFramework
Installation categoryIII
Type of installationIndoor installation
Measurement categoryCategory III 480 V
Electrical insulation classClass II
Connections - terminalsCurrent circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s) Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s)
Tightening torqueCurrent circuit: 0.9…1 N.m Philips No 2 screwdriver Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver Control circuit: 0.9…1 N.m Philips No 2 screwdriver
Wire stripping lengthCurrent circuit: 3.68 mm Voltage circuit: 7 mm Control circuit: 7 mm
StandardsIEC 61010-1:ed. 3 UL 61010-1:ed. 3
Product certificationsCE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 C-Tick
Width96 mm
DepthOutside : 13 mm Panel : 49 mm
Height96 mm
Net weight300 g
Electromagnetic compatibilityElectrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Emission tests conforming to FCC part 15 class A Emission tests conforming to FCC part 15 Subpart C Emission tests conforming to FCC part 15 Subpart E
Overvoltage categoryIII
IP degree of protectionIP51 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529
Relative humidity5…95 % at 50 °C
Pollution degree2
Ambient air temperature for operation-10…60 °C
Ambient air temperature for storage-20…70 °C
Operating altitude<= 2000 m
service life7 year(s)

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.