AurFort
Harmony XACSchneider Electric pendant control station XAC-A - 6 pushbuttons, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

PENDANT CONTROL STATION

pendant control station XAC-A - 6 pushbuttons

SKU XACA691

Schneider Electric XACA691 is a pendant control station in the Harmony XAC range. Key specifications include ip protection: IP65 conforming to IEC 60529; product range: Harmony XAC; product type: Pendant control station.

IP65 conforming to IEC 60529IP protection
Harmony XACProduct range
Pendant control stationProduct type
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 18, 2026.

XACA691 — selected manufacturer specifications
Product referenceXACA691
Range of productHarmony XAC
Product or component typePendant control station
Device short nameXACA
Control station typeDouble insulated
Enclosure materialPolypropylene
Electrical circuit typeControl circuit
enclosure typeComplete ready for use
Control station applicationControl of 2-speed hoist motor
Mechanical interlockingWith mechanical interlocking between pairs
Control station colourYellow
Connections - terminalsScrew clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end Screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end
Protective treatmentTH
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…70 °C
Vibration resistance15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Shock resistance100 gn conforming to IEC 60068-2-27
Overvoltage categoryClass II conforming to IEC 61140
IP degree of protectionIP65 conforming to IEC 60529
IK degree of protectionIK08 conforming to IEC 62262
Mechanical durability1000000 cycles
Cable entryRubber sleeve with stepped entry 8…26 mm
Contact code designationA600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current10 A
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
Contact operationSlow-break
Maximum resistance across terminals25 MOhm
Short-circuit protection10 A fuse protection by cartridge fuse type gG
Rated operational power in W40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.