AurFort
Harmony XB4Schneider Electric Red Ø40 Emergency stop, switching off Ø22 latching turn release 2NC, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

EMERGENCY STOP PUSH-BUTTON EMERGENCY SWITCHING OFF PUSH-BUTTON

Red Ø40 Emergency stop, switching off Ø22 latching turn release 2NC

SKU XB4BS8444

Schneider Electric XB4BS8444 is a emergency stop push-button emergency switching off push-button in the Harmony XB4 range. Key specifications include operational current: 3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1; ip protection: IP66 conforming to IEC 60529; net weight: 0.13 kg.

3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1Operational current
IP66 conforming to IEC 60529IP protection
0.13 kgNet weight
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 18, 2026.

XB4BS8444 — selected manufacturer specifications
Product referenceXB4BS8444
Range of productHarmony XB4
Product or component typeEmergency stop push-button Emergency switching off push-button
Device short nameXB4
Bezel materialChromium plated metal
Fixing collar materialZamak
Mounting diameter22.5 mm
Sale per indivisible quantity1
Shape of signaling unit headRound
Type of operatortrigger action and mechanical latching
Head typeStandard
ResetTurn to release
Operator profileRed mushroom Ø 40 mm, unmarked
Contact operationSlow-break
Connections - terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1
Height47 mm
Width40 mm
Depth82 mm
Terminals description ISO n°1(21-22)NC
Net weight0.13 kg
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
Contacts type and composition2 NC
Contacts usageStandard contacts
Positive openingWith conforming to IEC 60947-5-1 appendix K
Operating travel1.5 mm (NC changing electrical state) 4.3 mm (total travel)
Mechanical durability300000 cycles
Tightening torque0.8…1.2 N.m conforming to IEC 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to IEC 60947-5-4
Device presentationComplete product
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
Electrical shock protection classClass I conforming to IEC 60536
IP degree of protectionIP66 conforming to IEC 60529 IP67 IP69 IP69K
Enclosure TypeUL type 4X/13
IK degree of protectionIK06 conforming to IEC 50102
StandardsJIS C8201-5-1 IEC 60364-5-53 UL 508 IEC 60947-5-1 CSA C22.2 No 14 ISO 13850 IEC 60947-5-5 IEC 60947-1 IEC 60204-1 IEC 60947-5-4 JIS C8201-1
Product certificationsCSA LROS (Lloyds register of shipping) BV UL listed DNV
Vibration resistance5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.