AurFort
Harmony XB5Schneider Electric single contact block with body/fixing collar 2NO screw clamp terminal, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

COMPLETE BODY/CONTACT ASSEMBLY

single contact block with body/fixing collar 2NO screw clamp terminal

SKU ZB5AZ103

Schneider Electric ZB5AZ103 is a complete body/contact assembly in the Harmony XB5 range. Key specifications include ip protection: IP20 conforming to IEC 60529; product range: Harmony XB5; product type: Complete body/contact assembly.

IP20 conforming to IEC 60529IP protection
Harmony XB5Product range
Complete body/contact assemblyProduct type
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 18, 2026.

ZB5AZ103 — selected manufacturer specifications
Product referenceZB5AZ103
Range of productHarmony XB5
Product or component typeComplete body/contact assembly
Device short nameZB5
Fixing collar materialPlastic
Sale per indivisible quantity1
Head typeStandard
Contacts type and composition2 NO
Contact operationSlow-break
Contact block typeSingle
Connections - terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1
CAD overall width30 mm
CAD overall height42 mm
CAD overall depth32 mm
Terminals description ISO n°1(13-14)NO
Device compositionFixing collar Body
Contacts usageStandard contacts
Positive openingWithout
Operating travel2.6 mm (NO changing electrical state) 4.3 mm (total travel)
Mechanical durability10000000 cycles
Tightening torque0.8…1.2 N.m conforming to IEC 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to IEC 60947-5-4 Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to IEC 60947-5-4
Device presentationBasic sub-assemblies
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
IP degree of protectionIP20 conforming to IEC 60529
StandardsUL 508 IEC 60947-1 CSA C22.2 No 14 IEC 60947-5-4 IEC 60947-5-1 JIS C8201-5-1 JIS C8201-1
Product certificationsBV UL CSA DNV LROS (Lloyds register of shipping)
Vibration resistance5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.