AurFort
ABBESB100-20N-06ABB ESB100-20N-06, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

INSTALLATION CONTACTOR FOR DISTRIBUTION BOARD

ESB100-20N-06

SKU 1SAE361111R0620

ABB ESB100-20N-06: Installation contactor for distribution board. Pole configuration: 2P.

2PPoles
ESB100-20N-06Product range
Installation contactor for distribution boardProduct type
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 08, 2026.

1SAE361111R0620 — selected manufacturer specifications
Product ID1SAE361111R0620
Catalog DescriptionESB100-20N-06 Installation Contactors (NO) 100 A - 2 NO - 0 NC - 230 V - Control Circuit 400 Hz
Country of OriginIndia
Made To OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB015EXPU
Minimum Order Quantity1 piece
Customs Tariff Number85365080
EPLAN Data9AAC404721_EPLAN
Data Sheet, Technical Information2CDC103051C0201
Instructions and Manuals2CDC103043M6801
CAD Dimensional Drawing2CDC001079B0201
Product Net Width54 mm
Product Net Depth / Length65 mm
Product Net Height85 mm
Product Net Weight0.405 kg
Number of Main Contacts NO2
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Number of Poles2P
StandardsIEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 61095 UL 60947-1 UL 60947-4-1
Rated Operational VoltageMain Circuit 220 V DC Main Circuit 400 V AC
Rated Frequency (f)Control Circuit 400 Hz Control Circuit 50 Hz Control Circuit 60 Hz Control Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz Main Circuit DC
Rated Operational Current AC-1 (Ie)(NO) 100 A
Rated Operational Current AC-7a (Ie)(NO) 100 A
Rated Operational Power AC-1 (Pe)(230 V) Single Phase, NO 23 kW
Rated Operational Power AC-7a (Pe)(230 V) Single Phase, NO 23 kW
Rated Insulation Voltage (Ui)500 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Electrical DurabilityAC-1 (NO) 50000 cycle AC-7a (NO) 50000 cycle
Maximum Electrical Switching Frequency(AC-1) 150 cycles per hour (AC-7a) 150 cycles per hour
Mechanical DurabilityNr. Operations 1000000 cycle
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)230 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 7.5 V·A Average Holding Value DC 8.5 W Average Pull-in Value 50 Hz 90 V·A Average Pull-in Value 60 Hz 90 V·A Average Pull-in Value DC 100 W
Power Lossat Rated Operating Conditions AC-1 per Pole NO 6 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main CircuitFlexible with Ferrule 1x 10 ... 35 mm² Flexible with Insulated Ferrule 1x 10 ... 35 mm² Flexible 1x 10 ... 35 mm² Rigid 1x 10 ... 50 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1x 1 ... 2.5 mm² Flexible with Ferrule 2x 0.75 ... 1.5 mm² Flexible with Insulated Ferrule 1x 1 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1 mm² Flexible 1x 1 ... 2.5 mm² Flexible 2x 1 ... 1.5 mm² Rigid 1x 1 ... 4 mm² Rigid 2x 1 ... 2.5 mm²
Wire Stripping LengthControl Circuit 7 mm Main Circuit 15 mm
Degree of ProtectionIP20
Recommended Screw DriverControl Circuit Pozidriv 1 Main Circuit Pozidriv 2
Tightening TorqueControl Circuit 0.9 N·m Main Circuit 3 N·m
Terminal TypeScrew Terminals
Width in Number of Modular Spacings3
Product NameInstallation Contactors
Maximum Operating Voltage UL/CSAMain Circuit 480 V AC
General Use Rating UL/CSA(acc. to UL 480 V) 100 A
Connecting Capacity Main Circuit UL/CSASolid 8-0 AWG Stranded 8-0 AWG
Connecting Capacity Control Circuit UL/CSASolid 16-10 AWG Stranded 16-10 AWG
Tightening Torque UL/CSAControl Circuit 8 in·lb Main Circuit 27 in·lb
Ambient Air TemperatureOperation -25 ... +55 °C Storage -40 ... +80 °C
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
Pollution Degree3
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill UL 2799 Zero Waste To Landfill Validation available
ABB EcoSolutions Profile1SFC100125C0336
End Of Life Disassembling Instructions1SBC100156C0264
Environmental Product Declaration - EPD1SAC200434H0001
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 94.2 %
ABS Certificate1SAA920000-0101
CB Certificate1SAA920008-2001
CCC Certificate2024010304659822 2024010304659823
Declaration of Conformity - CE1SAD101100-3301
Declaration of Conformity - UKCA1SAD201100-3301
DNV Certificate1SAA920000-0306
RINA Certificate1SAA920000-0801
UL CertificateE191658-19960301
Package Level 1 Unitsbox 1 piece
Package Level 1 Width92 mm
Package Level 1 Depth / Length57 mm
Package Level 1 Height69.5 mm
Package Level 1 Gross Weight0.405 kg
Package Level 1 EAN4013614533037
IDEA Granular Category Code (IGCC)4759 >> Installation contactor for distribution board
E-Number (Finland)3707802
E-Number (Sweden)3210575

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.