ABBMS116-0.25

ABB catalog image for this SKU; may represent the product family.
MOTOR PROTECTION CIRCUIT-BREAKER
MS116-0.25
SKU 1SAM250000R1002ABB MS116-0.25: Motor protection circuit-breaker. Pole configuration: 3P.
3PPoles
MS116-0.25Product range
Motor protection circuit-breakerProduct type
PRODUCT DATA
Technical specifications
Source: ABB English regional product catalog.
Verified September 09, 2026.
| Product ID | 1SAM250000R1002 |
|---|---|
| Catalog Description | MS116-0.25 Manual Motor Starter 0.16 ... 0.25 A |
| Configuration Only | No |
| Country of Origin | Finland India |
| Criticality | No |
| Lead Time | 999 day 0 day |
| Made To Order | No |
| Note | No |
| Product Availability Class | Replaced |
| Product Sales Status | Active |
| Quote Only | No |
| Replacement Part ID | 68943973 |
| Stocked At Warehouses | BRAPR001EXPU CHNOR001EXPU CLABB001EXPU CNIAB001EXPU COABB001EXPU DEAPRMLCEXPU DKSER001EXPU DUABB001EXPU DUABB003EXPU EESER001EXPU EGAUT001EXPU ESATD001EXPU FISER001EXPU FRAUT001EXPU GBINS001EXPU GRABB001EXPU INABB015EXPU INABB039EXPU INABBRLCEXPU ITIND002EXPU NLABB021EXPU NOATDRLCEXPU SGIND002EXPU TRDMD001EXPU USABB251EXPU ZATAD021EXPU |
| Storage Location | 4001 |
| Warranty Return | Product under warranty must be returned |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362010 |
| Data Sheet, Technical Information | 2CDC131025D0201 |
| Instructions and Manuals | 2CDC131011M6802 |
| Instructions and Manuals (Part 2) | 2CDC131060M0202 |
| Time-Current Characteristic Curve | 1SAM200505F0102 |
| I²t Characteristic | 1SAM200507F0001 1SAM200507F0002 1SAM200507F0003 |
| Cut-off Current Characteristic | 1SAM200508F0001 1SAM200508F0002 1SAM200508F0003 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimension Diagram | 1SAM200422F0001 |
| Product Net Width | 45 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 85.6 mm |
| Product Net Weight | 0.225 kg |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 50 kA (400 V AC) 50 kA (440 V AC) 50 kA (500 V AC) 30 kA (690 V AC) 30 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 100 kA (500 V AC) 100 kA (690 V AC) 100 kA |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 3.1 A |
| Setting Range | 0.16 ... 0.25 A |
| Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 0.06 kW |
| Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 0.06 kW |
| Rated Operational Voltage | Main Circuit 690 V AC |
| Rated Operational Current (Ie) | 0.25 A |
| Rated Operational Current AC-3 (Ie) | 0.25 A |
| Rated Operational Current AC-3e (Ie) | 0.25 A |
| Rated Frequency (f) | Main Circuit 50 Hz Main Circuit 60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
| Rated Insulation Voltage (Ui) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 0.7 ... 1.6 W |
| Number of Poles | 3P |
| Conventional Free-air Thermal Current (Ith) | Main Circuit 0.25 A |
| Degree of Protection | Housing IP20 Main Circuit Terminals IP10 |
| Pollution Degree | 3 |
| Electrical Durability | 100000 cycle |
| Mechanical Durability | Nr. Operations 100000 cycle |
| Terminal Type | Screw Terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² |
| Tightening Torque | Main Circuit 0.8 ... 1.2 N·m |
| Wire Stripping Length | Main Circuit 9 mm |
| Recommended Screw Driver | Pozidriv 2 |
| Mounting Position | 1 ... 6 any |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 400 V 0 mm Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm Electrical Conductive Board, Vertical 75 mm Other Device Same Type, Horizontal 0 mm Other Device Same Type, Vertical 150 mm |
| Contact Position Indication | ON / OFF |
| Standards | IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L |
| Short-Circuit Current Rating (SCCR) | Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 30 kA Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Full Load Amps Motor Use | (110 ... 120 V AC) Three Phase 0.25 A (200 V AC) Three Phase 0.25 A (208 V AC) Three Phase 0.25 A (220 ... 240 V AC) Three Phase 0.25 A (440 ... 480 V AC) Three Phase 0.25 A (550 ... 600 V AC) Three Phase 0.25 A |
| Locked Rotor Amps | (110 ... 120 V AC) Three Phase 1.5 A (200 V AC) Three Phase 1.5 A (208 V AC) Three Phase 1.5 A (220 ... 240 V AC) Three Phase 1.5 A (440 ... 480 V AC) Three Phase 1.5 A (550 ... 600 V AC) Three Phase 1.5 A |
| General Use Rating UL/CSA | (600 V AC) 0.25 A |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-12 AWG Stranded 1/2x 16-12 AWG |
| Tightening Torque UL/CSA | Main Circuit 10 in·lb |
| Ambient Air Temperature | Around the Enclosure 0 ... +40 °C Operation -25 ... +70 °C Operation Compensated -25 ... +55 °C Storage -50 ... +80 °C |
| Ambient Air Temperature Compensation | Yes |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to Vibrations | 2g 5 ... 150 Hz 5g 3 ... 150 Hz |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SAA963005-4502 |
| RoHS Declaration | 1SAA963006-4501 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006539 |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| ABB EcoSolutions Profile | 1SFC100125C0353 |
| End Of Life Disassembling Instructions | 1SAC200331H0001 |
| Environmental Product Declaration - EPD | 1SAC200359H0001 1SAC200384H0001 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 88 % |
| A2L Certificate – IEC | 1SAA963000-4601 |
| ABS Certificate | 1SAA963000-0104 |
| BV Certificate | 1SAA963000-0204 |
| CB Certificate | 1SAA963005-2003 1SAA963006-2001 |
| CCC Certificate | 2024010307654705 2024010307656673 |
| CQC Certificate | CQC2011010307506570 CQC2014010307744794 |
| Declaration of Conformity - CCC | 2020980307003705 2020980307003043 |
| Declaration of Conformity - CE | 1SAD101100-3401 |
| Declaration of Conformity - UKCA | 1SAD201100-3401 |
| DNV Certificate | 1SAA963000-0304 |
| DNV GL Certificate | 1SAA963000-0304 |
| EAC Certificate | 1SAA963000-2701 |
| GL Certificate | 1SAA963000-0402 |
| LR Certificate | 1SAA963000-0505 |
| RMRS Certificate | 1SAA918000-0704 |
| UL Certificate | E137861-20001218 |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 92 mm |
| Package Level 1 Depth / Length | 95 mm |
| Package Level 1 Height | 50 mm |
| Package Level 1 Gross Weight | 0.24 kg |
| Package Level 1 EAN | 4013614320255 |
| Package Level 2 Units | carton 40 piece |
| Package Level 2 Width | 280 mm |
| Package Level 2 Depth / Length | 395 mm |
| Package Level 2 Height | 210 mm |
| Package Level 2 Gross Weight | 9.986 kg |
| Package Level 2 EAN | 4013614408625 |
| IDEA Granular Category Code (IGCC) | 4731 >> Manual Starters |
| E-Number (Finland) | 3706002 |
| E-Number (Norway) | 4364268 |
| E-Number (Sweden) | 3111932 |
For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.
Browse circuit breakers →Browse motor protection circuit breakers →