AurFort
ABBMS116-2.5ABB MS116-2.5, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

MOTOR PROTECTION CIRCUIT-BREAKER

MS116-2.5

SKU 1SAM250000R1007

ABB MS116-2.5: Motor protection circuit-breaker. Pole configuration: 3P.

3PPoles
MS116-2.5Product range
Motor protection circuit-breakerProduct type
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 09, 2026.

1SAM250000R1007 — selected manufacturer specifications
Product ID1SAM250000R1007
Catalog DescriptionMS116-2.5 Manual Motor Starter 1.6 ... 2.5 A
Configuration OnlyNo
Country of OriginFinland India
CriticalityNo
Lead Time999 day 0 day
Made To OrderNo
NoteNo
Product Availability ClassReplaced
Product Sales StatusActive
Quote OnlyNo
Replacement Part ID64697692
Stocked At WarehousesBRAPR001EXPU CHNOR001EXPU CLABB001EXPU CNIAB001EXPU COABB001EXPU DEAPRMLCEXPU DKSER001EXPU DUABB001EXPU DUABB003EXPU EESER001EXPU EGAUT001EXPU ESATD001EXPU FISER001EXPU FRAUT001EXPU GBINS001EXPU GRABB001EXPU INABB015EXPU INABB039EXPU INABBRLCEXPU ITIND002EXPU NLABB021EXPU NOATDRLCEXPU SGIND002EXPU TRDMD001EXPU USABB251EXPU ZATAD021EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned
Minimum Order Quantity1 piece
Customs Tariff Number85362010
Data Sheet, Technical Information2CDC131025D0201
Instructions and Manuals2CDC131011M6802
Instructions and Manuals (Part 2)2CDC131060M0202
Time-Current Characteristic Curve1SAM200505F0107
I²t Characteristic1SAM200507F0001 1SAM200507F0002 1SAM200507F0003
Cut-off Current Characteristic1SAM200508F0001 1SAM200508F0002 1SAM200508F0003
CAD Dimensional Drawing2CDC001079B0201
Dimension Diagram1SAM200422F0001
Product Net Width45 mm
Product Net Height90 mm
Product Net Depth / Length85.6 mm
Product Net Weight0.265 kg
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 50 kA (400 V AC) 50 kA (440 V AC) 10 kA (500 V AC) 10 kA (690 V AC) 5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 75 kA (400 V AC) 75 kA (440 V AC) 30 kA (500 V AC) 20 kA (690 V AC) 10 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)31.3 A
Setting Range1.6 ... 2.5 A
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 0.75 kW
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 0.75 kW
Rated Operational VoltageMain Circuit 690 V AC
Rated Operational Current (Ie)2.5 A
Rated Operational Current AC-3 (Ie)2.5 A
Rated Operational Current AC-3e (Ie)2.5 A
Rated Frequency (f)Main Circuit 50 Hz Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Power Lossat Rated Operating Conditions per Pole 0.7 ... 1.8 W
Number of Poles3P
Conventional Free-air Thermal Current (Ith)Main Circuit 2.5 A
Degree of ProtectionHousing IP20 Main Circuit Terminals IP10
Pollution Degree3
Electrical Durability100000 cycle
Mechanical DurabilityNr. Operations 100000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm²
Tightening TorqueMain Circuit 0.8 ... 1.2 N·m
Wire Stripping LengthMain Circuit 9 mm
Recommended Screw DriverPozidriv 2
Mounting Position1 ... 6 any
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 400 V 0 mm Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm Electrical Conductive Board, Vertical 75 mm Other Device Same Type, Horizontal 0 mm Other Device Same Type, Vertical 150 mm
Contact Position IndicationON / OFF
StandardsIEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L
Short-Circuit Current Rating (SCCR)Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 30 kA Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Horsepower Rating UL/CSA(200 V AC) Three Phase 0.5 Hp (208 V AC) Three Phase 0.5 Hp (220 ... 240 V AC) Three Phase 0.5 Hp (440 ... 480 V AC) Three Phase 1 Hp (550 ... 600 V AC) Three Phase 1.5 Hp
Full Load Amps Motor Use(200 V AC) Three Phase 2.5 A (208 V AC) Three Phase 2.5 A (220 ... 240 V AC) Three Phase 2.5 A (440 ... 480 V AC) Three Phase 2.5 A (550 ... 600 V AC) Three Phase 2.5 A
Locked Rotor Amps(200 V AC) Three Phase 15 A (208 V AC) Three Phase 15 A (220 ... 240 V AC) Three Phase 15 A (440 ... 480 V AC) Three Phase 15 A (550 ... 600 V AC) Three Phase 15 A
General Use Rating UL/CSA(600 V AC) 2.5 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-12 AWG Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSAMain Circuit 10 in·lb
Ambient Air TemperatureAround the Enclosure 0 ... +40 °C Operation -25 ... +70 °C Operation Compensated -25 ... +55 °C Storage -50 ... +80 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations2g 5 ... 150 Hz 5g 3 ... 150 Hz
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SAA963005-4502
RoHS Declaration1SAA963006-4501
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006539
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
ABB EcoSolutions Profile1SFC100125C0353
End Of Life Disassembling Instructions1SAC200331H0001
Environmental Product Declaration - EPD1SAC200359H0001 1SAC200384H0001
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 88 %
A2L Certificate – IEC1SAA963000-4601
ABS Certificate1SAA963000-0104
BV Certificate1SAA963000-0204
CB Certificate1SAA963005-2003 1SAA963006-2001
CCC Certificate2024010307654705 2024010307656673
CQC CertificateCQC2011010307506570 CQC2014010307744794
Declaration of Conformity - CCC2020980307003705 2020980307003043
Declaration of Conformity - CE1SAD101100-3401
Declaration of Conformity - UKCA1SAD201100-3401
DNV Certificate1SAA963000-0304
DNV GL Certificate1SAA963000-0304
EAC Certificate1SAA963000-2701
GL Certificate1SAA963000-0402
LR Certificate1SAA963000-0505
RMRS Certificate1SAA918000-0704
UL CertificateE137861-20001218
Package Level 1 Unitsbox 1 piece
Package Level 1 Width92 mm
Package Level 1 Depth / Length95 mm
Package Level 1 Height50 mm
Package Level 1 Gross Weight0.28 kg
Package Level 1 EAN4013614320309
Package Level 2 Unitscarton 40 piece
Package Level 2 Width280 mm
Package Level 2 Depth / Length395 mm
Package Level 2 Height210 mm
Package Level 2 Gross Weight11.586 kg
Package Level 2 EAN4013614408670
IDEA Granular Category Code (IGCC)4731 >> Manual Starters
E-Number (Finland)3706007
E-Number (Norway)4364273
E-Number (Sweden)3111942

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.