ABBMS132-6.3

ABB catalog image for this SKU; may represent the product family.
MOTOR PROTECTION CIRCUIT-BREAKER
MS132-6.3
SKU 1SAM350000R1009ABB MS132-6.3: Motor protection circuit-breaker. Pole configuration: 3P.
3PPoles
MS132-6.3Product range
Motor protection circuit-breakerProduct type
PRODUCT DATA
Technical specifications
Source: ABB English regional product catalog.
Verified September 09, 2026.
| Product ID | 1SAM350000R1009 |
|---|---|
| Catalog Description | MS132-6.3 Manual Motor Starter 4.0 ... 6.3 A |
| Country of Origin | Germany China India |
| Lead Time | 0 day 19 day 28 day 21 day 26 day |
| Made To Order | No |
| Warranty Return | Product under warranty must be returned |
| Product Sales Status | Active Inactive |
| Quote Only | No |
| Stocked At Warehouses | AETAD009EXPU BRABB008EXPU BRAPR001EXPU CHNOR001EXPU CHSEC006EXPU CLABB001EXPU CNIAB001EXPU COABB001EXPU CZABB006EXPU DEAPRMLCEXPU DKSER001EXPU DUABB001EXPU DUABB003EXPU EESER001EXPU EGAUT001EXPU ESATD001EXPU FISER001EXPU FRAUT001EXPU GBINS001EXPU GRABB001EXPU INABB015EXPU INABB039EXPU INABBRLCEXPU ITIND002EXPU NLABB021EXPU NOATDRLCEXPU SGIND002EXPU TRDMD001EXPU USABB251EXPU USSVCEXPU ZATAD021EXPU |
| Configuration Only | No |
| Criticality | No |
| Note | No |
| Product Availability Class | From stock if available, otherwise Target delivery time is |
| Storage Location | 4001 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362010 |
| Data Sheet, Technical Information | 2CDC131021D0202 |
| Instructions and Manuals | 2CDC131022M6802 |
| Instructions and Manuals (Part 2) | 2CDC131060M0202 |
| Ex Operating Instructions | 2CDC131063M6801 |
| Time-Current Characteristic Curve | 1SAM300505F0009 |
| I²t Characteristic | 1SAM300507F0001 1SAM300507F0003 1SAM300507F0002 |
| Cut-off Current Characteristic | 1SAM300508F0001 1SAM300508F0003 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimension Diagram | 1SAM300402F0001 |
| Product Net Width | 45 mm |
| Product Net Height | 90 mm |
| Product Net Depth / Length | 86.75 mm |
| Product Net Weight | 0.265 kg |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 100 kA (250 V DC) 3 Poles in Series 10 kA (400 V AC) 100 kA (440 V AC) 30 kA (500 V AC) 20 kA (690 V AC) 3 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 30 kA (500 V AC) 20 kA (690 V AC) 3 kA |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 78.8 A |
| Setting Range | 4.0 ... 6.3 A |
| Rated Operational Power AC-3 (Pe) | (400 V) Three Phase 2.2 kW |
| Rated Operational Power AC-3e (Pe) | (400 V) Three Phase 2.2 kW |
| Rated Operational Voltage | Main Circuit 690 V AC Main Circuit 250 V DC |
| Rated Operational Current (Ie) | 6.3 A |
| Rated Operational Current AC-3 (Ie) | 6.3 A |
| Rated Operational Current AC-3e (Ie) | 6.3 A |
| Rated Operational Current DC-5 (Ie) | 6.3 A |
| Rated Frequency (f) | Main Circuit 50 Hz Main Circuit 60 Hz |
| Operating Frequency (fsw) | 0 ... 400 Hz |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
| Rated Insulation Voltage (Ui) | 690 V |
| Power Loss | at Rated Operating Conditions per Pole 0.7 ... 1.8 W |
| Number of Poles | 3P |
| Conventional Free-air Thermal Current (Ith) | Main Circuit 6.3 A |
| Degree of Protection | Housing IP20 Main Circuit Terminals IP10 |
| Pollution Degree | 3 |
| Electrical Durability | 50000 cycle |
| Mechanical Durability | Nr. Operations 100000 cycle |
| Terminal Type | Screw Terminals |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² |
| Tightening Torque | Main Circuit 0.8 ... 1.2 N·m |
| Wire Stripping Length | Main Circuit 9 mm |
| Recommended Screw Driver | Pozidriv 2 |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Minimum Mounting Distance | Electrical Conductive Board, Horizontal - Up to 400 V 0 mm Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm Electrical Conductive Board, Vertical 75 mm Other Device Same Type, Horizontal 0 mm Other Device Same Type, Vertical 150 mm |
| Contact Position Indication | ON / OFF / TRIP |
| Standards | IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L |
| Remarks | UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx |
| Short-Circuit Current Rating (SCCR) | Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 18 kA Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 1 Hp (208 V AC) Three Phase 1 Hp (220 ... 240 V AC) Three Phase 1.5 Hp (440 ... 480 V AC) Three Phase 3 Hp (550 ... 600 V AC) Three Phase 5 Hp |
| Full Load Amps Motor Use | (200 V AC) Three Phase 6.3 A (208 V AC) Three Phase 6.3 A (220 ... 240 V AC) Three Phase 6.3 A (440 ... 480 V AC) Three Phase 4.8 A (550 ... 600 V AC) Three Phase 6.1 A |
| Locked Rotor Amps | (200 V AC) Three Phase 37.8 A (208 V AC) Three Phase 37.8 A (220 ... 240 V AC) Three Phase 37.8 A (440 ... 480 V AC) Three Phase 32 A (550 ... 600 V AC) Three Phase 36.8 A |
| General Use Rating UL/CSA | (600 V AC) 6.3 A |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-12 AWG Stranded 1/2x 16-12 AWG |
| Tightening Torque UL/CSA | Main Circuit 10 ... 12 in·lb |
| Ambient Air Temperature | Around the Enclosure 0 ... +40 °C Operation -25 ... +70 °C Operation Compensated -25 ... +60 °C Storage -50 ... +80 °C |
| Ambient Air Temperature Compensation | Yes |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to Vibrations | 5g 3 ... 150 Hz |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SAA963005-4502 |
| RoHS Declaration | 1SAA963006-4501 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006539 |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill UL 2799 Zero Waste To Landfill Validation available |
| ABB EcoSolutions Profile | 1SFC100125C0353 |
| End Of Life Disassembling Instructions | 1SAC200332H0001 |
| Environmental Product Declaration - EPD | 1SAC200360H0001 1SAC200385H0001 |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 80 % |
| A2L Certificate – IEC | 1SAA963000-4601 |
| ABS Certificate | 1SAA963001-0101 |
| ATEX Certificate | 1SAA963000-3902 |
| BV Certificate | 1SAA963001-0202 |
| CB Certificate | 1SAA963002-2002 1SAA963007-2002 |
| CCC Certificate | 2024010307654702 2024010307658958 |
| CQC Certificate | CQC2010010307387700 CQC2019010307243864 |
| Declaration of Conformity - CCC | 2020980307003526 2020980307003041 |
| Declaration of Conformity - CE | 1SAD101100-3402 |
| Declaration of Conformity - UKCA | 1SAD201100-3402 |
| DNV GL Certificate | 1SAA963001-0304 |
| EAC Certificate | 1SAA963000-2701 |
| IECEx Certificate | 1SAA963000-4001 |
| LR Certificate | 1SAA963001-0503 |
| RINA Certificate | 1SAA963002-0802 |
| RMRS Certificate | 1SAA918000-0704 |
| UL Certificate | E137861-20090225 E345003-20090225 |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 92 mm |
| Package Level 1 Depth / Length | 95 mm |
| Package Level 1 Height | 50 mm |
| Package Level 1 Gross Weight | 0.28 kg |
| Package Level 1 EAN | 4013614400094 |
| Package Level 2 Units | carton 40 piece |
| Package Level 2 Width | 280 mm |
| Package Level 2 Depth / Length | 395 mm |
| Package Level 2 Height | 210 mm |
| Package Level 2 Gross Weight | 11.586 kg |
| Package Level 2 EAN | 4013614408991 |
| IDEA Granular Category Code (IGCC) | 4731 >> Manual Starters |
| E-Number (Finland) | 3705993 |
| E-Number (Norway) | 4364078 |
| E-Number (Sweden) | 3112125 |