AurFort
ABBMS165-73ABB MS165-73, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

MOTOR PROTECTION CIRCUIT-BREAKER

MS165-73

SKU 1SAM451000R1018

ABB MS165-73: Motor protection circuit-breaker. Pole configuration: 3P.

3PPoles
MS165-73Product range
Motor protection circuit-breakerProduct type
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 09, 2026.

1SAM451000R1018 — selected manufacturer specifications
Product ID1SAM451000R1018
Catalog DescriptionMS165-73 Manual Motor Starter 62 ... 73 A
Country of OriginIndia
Lead Time10 week
Made To OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB015EXPU
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Data Sheet, Technical Information2CDC131083D0201
Instructions and Manuals2CDC131081M6801
Instructions and Manuals (Part 2)2CDC131060M0202
Ex Operating Instructions2CDC131087M6801
Time-Current Characteristic Curve1SAM400505F0008
I²t Characteristic1SAM400506F0001
Cut-off Current Characteristic1SAM400507F0001
CAD Dimensional Drawing2CDC001079B0201
Dimension Diagram1SAM400401F0001
Product Net Width55 mm
Product Net Height142.65 mm
Product Net Depth / Length122 mm
Product Net Weight1 kg
Rated Service Short-Circuit Breaking Capacity (Ics)(230 V AC) 30 kA (250 V DC) 3 Poles in Series 100 kA (400 V AC) 30 kA (440 V AC) 18 kA (500 V AC) 10 kA (690 V AC) 6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(230 V AC) 30 kA (250 V DC) 100 kA (400 V AC) 30 kA (440 V AC) 18 kA (500 V AC) 10 kA (690 V AC) 8 kA
Rated Instantaneous Short-Circuit Current Setting (Ii)1022 A
Setting Range62 ... 73 A
Rated Operational Power AC-3 (Pe)(400 V) Three Phase 37 kW
Rated Operational Power AC-3e (Pe)(400 V) Three Phase 37 kW
Rated Operational VoltageMain Circuit 690 V AC Main Circuit 250 V DC
Rated Operational Current (Ie)73 A
Rated Operational Current AC-3 (Ie)73 A
Rated Operational Current AC-3e (Ie)73 A
Rated Operational Current DC-5 (Ie)73 A
Rated Frequency (f)Main Circuit 50 Hz Main Circuit 60 Hz
Operating Frequency (fsw)0 ... 415 Hz
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Rated Insulation Voltage (Ui)1000 V
Power Lossat Rated Operating Conditions per Pole 5.22 ... 6.92 W
Number of Poles3P
Conventional Free-air Thermal Current (Ith)Main Circuit 73 A
Degree of ProtectionHousing IP20 Main Circuit Terminals IP10
Pollution Degree3
Electrical Durability20000 cycle
Mechanical DurabilityNr. Operations 50000 cycle
Terminal TypeScrew Terminals
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 1 ... 35 mm² Flexible with Insulated Ferrule 1/2x 1 ... 35 mm² Flexible 1/2x 1 ... 35 mm² Rigid 1/2x 1 ... 4 mm² Solid 1/2x 1 ... 4 mm² Stranded 1/2x 1 ... 50 mm²
Tightening TorqueMain Circuit 4 N·m
Wire Stripping LengthMain Circuit 16 mm
Recommended Screw DriverPozidriv 2
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting DistanceElectrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm Electrical Conductive Board, Horizontal - Up to 400 V 0 mm Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm Electrical Conductive Board, Vertical 75 mm Other Device Same Type, Horizontal 0 mm Other Device Same Type, Vertical 150 mm
Contact Position IndicationON / OFF / TRIP
StandardsCSA 22.2 No. 14 IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-4-1
Short-Circuit Current Rating (SCCR)Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 50 kA Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 50 kA Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 10 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 50 kA Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 10 kA Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 50 kA Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 10 kA
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Horsepower Rating UL/CSA(200 V AC) Three Phase 20 Hp (208 V AC) Three Phase 20 Hp (220 ... 240 V AC) Three Phase 25 Hp (440 ... 480 V AC) Three Phase 50 Hp (550 ... 600 V AC) Three Phase 60 Hp
Full Load Amps Motor Use(110 ... 120 V AC) Three Phase 56 A (200 V AC) Three Phase 62.1 A (208 V AC) Three Phase 59.4 A (220 ... 240 V AC) Three Phase 68 A (440 ... 480 V AC) Three Phase 65 A (550 ... 600 V AC) Three Phase 62 A
Locked Rotor Amps(200 V AC) Three Phase 334 A (208 V AC) Three Phase 321 A (220 ... 240 V AC) Three Phase 365 A (440 ... 480 V AC) Three Phase 363 A (550 ... 600 V AC) Three Phase 348 A
General Use Rating UL/CSA(600 V AC) 73 A
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 16-0 AWG Stranded 1/2x 16-0 AWG
Tightening Torque UL/CSAMain Circuit 35 in·lb
Ambient Air TemperatureOperation -25 ... +70 °C Operation Compensated -25 ... +60 °C Storage -50 ... +80 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to VibrationsMounted on Mounting Plate: 5g 3 ... 150 Hz Mounted on DIN-Rail: 4g 3 ... 150 Hz
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SAA963005-4502
RoHS Declaration1SAA963006-4501
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006539
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
ABB EcoSolutions Profile1SFC100125C0353
End Of Life Disassembling Instructions1SAC200284H0001
Environmental Product Declaration - EPD1SAC200253H0001
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 93.1 %
ATEX Certificate1SAA918001-3901
CB Certificate1SAA918002-2002
CCC Certificate2024010307654703 2025010307838569
CQC CertificateCQC2015010307760141
Declaration of Conformity - CCC2020980307003042
Declaration of Conformity - CE1SAD101100-3408
Declaration of Conformity - UKCA1SAD201100-3408
EAC Certificate1SAA963000-2701
IECEx Certificate1SAA918000-4001
UL CertificateE137861-20150206 E345003-20150206
Package Level 1 Unitsbox 1 piece
Package Level 1 Width64 mm
Package Level 1 Depth / Length177 mm
Package Level 1 Height140 mm
Package Level 1 Gross Weight1.1 kg
Package Level 1 EAN4013614536625
Package Level 2 Unitscarton 12 piece
Package Level 2 Width330 mm
Package Level 2 Depth / Length400 mm
Package Level 2 Height320 mm
Package Level 2 Gross Weight13 kg
Package Level 2 EAN4013614537813
IDEA Granular Category Code (IGCC)4731 >> Manual Starters
E-Number (Finland)3708083
E-Number (Norway)4364127
E-Number (Sweden)3110788

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.