ELECTRONIC OVERLOAD RELAY

EF45-45

SKU 1SAX221001R1102

ABB EF45-45: Electronic overload relay. Pole configuration: 3P.

3PPoles
EF45-45Product range
Electronic overload relayProduct type
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 09, 2026.

1SAX221001R1102 — selected manufacturer specifications
Product ID1SAX221001R1102
Catalog DescriptionEF45-45 Electronic Overload Relay 15 ... 45 A
Country of OriginChina India
Lead Time0 day 28 day
Made To OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesAETAD009EXPU BRABB008EXPU CHSEC006EXPU CZABB006EXPU INABB015EXPU
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Data Sheet, Technical Information2CDC107025D0201
Instructions and Manuals2CDC107024M6803
Instructions and Manuals (Part 2)1SAC200017M0002
Ex Operating Instructions2CDC107043M6801
Time-Current Characteristic Curve1SAX100509F0002 1SAX100510F0001
CAD Dimensional Drawing2CDC001079B0201
Dimension Diagram1SAX200403F0001
Product Net Width45 mm
Product Net Height104.7 mm
Product Net Depth / Length86 mm
Product Net Weight0.362 kg
Setting Range15 ... 45 A
Rated Operational VoltageAuxiliary Circuit 600 V AC/DC Main Circuit 690 V AC
Rated Operational Current (Ie)45 A
Rated Frequency (f)Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Number of Poles3P
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number of Protected Poles3
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit NC 6 A Auxiliary Circuit NO 6 A
Rated Operational Current AC-15 (Ie)(240 V) NC 3 A (240 V) NO 3 A (400 V) NC 1.1 A (400 V) NO 1.1 A (500 V) NC 0.75 A (500 V) NO 0.75 A
Rated Operational Current DC-13 (Ie)(125 V) NC 0.55 A (125 V) NO 0.5 A (24 V) NC 1.5 A (24 V) NO 1.5 A (250 V) NC 0.27 A (250 V) NO 0.27 A (60 V) NC 0.55 A (60 V) NO 0.55 A
Degree of ProtectionIP20
Pollution Degree3
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 2.5 ... 10 mm² Flexible with Insulated Ferrule 1/2x 2.5 ... 10 mm² Flexible 1/2x 2.5 ... 10 mm² Rigid 1/2x 2.5 ... 16 mm²
Tightening TorqueAuxiliary Circuit 0.8 ... 1.2 N·m Main Circuit 2.3 ... 2.6 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm Main Circuit 13 mm
Recommended Screw DriverAuxiliary Circuit Pozidriv 2 Main Circuit Pozidriv 2
Mounting Position1 ... 6
Power Lossat Rated Operating Conditions per Pole 0.059 ... 0.527 W
Suitable ForAF26 AF30 AF38
StandardsIEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Contact Rating UL/CSA(NC:) B600 (NC:) Q600 (NO:) B600 (NO:) Q600
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 14-6 AWG Stranded 1/2x 14-6 AWG
Connecting Capacity Auxiliary Circuit UL/CSAFlexible 1/2x 18-10 AWG Stranded 1/2x 18-10 AWG
Tightening Torque UL/CSAAuxiliary Circuit 7 ... 1 in·lb Main Circuit 35 in·lb
Ambient Air TemperatureOperation -25 ... +70 °C Operation Compensated -25 ... +70 °C Storage -50 ... +80 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations5g 3 ... 150 Hz
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
ABB EcoSolutions Profile1SFC100125C0415
End Of Life Disassembling Instructions1SAC200380H0001
Environmental Information1SAC200097H0001
Environmental Product Declaration - EPD1SAC200356H0001
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 89.2 %
ABS Certificate1SAA941002-0102
ATEX Certificate1SAA941004-3901
BV Certificate1SAA941002-0201
CB Certificate1SAA964003-2002
CCC Certificate2024010304654684
CCS Certificate1SAA941001-0901
CQC CertificateCQC2006010309192161
Declaration of Conformity - CCC2020980309000293
Declaration of Conformity - CE1SAD101100-3601
Declaration of Conformity - UKCA1SAD201100-3601
DNV Certificate1SAA941003-0302
EAC Certificate1SAA941003-2701
IECEx Certificate1SAA941000-4001
LR Certificate1SAA941002-0501
RINA CertificateRINA_ELE376813CS
RMRS Certificate1SAA964000-0703
UL CertificateE48139-19990512
Package Level 1 Unitsbox 1 piece
Package Level 1 Width111 mm
Package Level 1 Height51.5 mm
Package Level 1 Depth / Length93 mm
Package Level 1 Gross Weight0.398 kg
Package Level 1 EAN4013614403972
IDEA Granular Category Code (IGCC)5365 >> Electronic overload relay
E-Number (Finland)3706157
E-Number (Norway)4116836
E-Number (Sweden)3224186

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.