AurFort
ABBTA200DU-175ABB TA200DU-175, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

THERMAL OVERLOAD RELAY

TA200DU-175

SKU 1SAZ421201R1005

ABB TA200DU-175: Thermal overload relay. Pole configuration: 3P.

3PPoles
TA200DU-175Product range
Thermal overload relayProduct type
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 09, 2026.

1SAZ421201R1005 — selected manufacturer specifications
Product ID1SAZ421201R1005
Catalog DescriptionTA200DU-175 Thermal Overload Relay 130 ... 175 A
Country of OriginIndia
Made To OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB015EXPU
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Data Sheet, Technical Information1SBC100214C0202
Instructions and Manuals2CDC106028M6802
Instructions and Manuals (Part 2)1SAC200017M0002
Time-Current Characteristic Curve1SAZ400502F0005
CAD Dimensional Drawing2CDC001079B0201
Dimension Diagram1SAZ400401F0001
Product Net Width104 mm
Product Net Height151 mm
Product Net Depth / Length126 mm
Product Net Weight0.77 kg
Setting Range130 ... 175 A
Rated Operational VoltageAuxiliary Circuit 440 V DC Auxiliary Circuit 500 V AC Main Circuit 690 V AC Main Circuit 440 V DC
Rated Operational Current (Ie)175 A
Rated Frequency (f)Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Number of Poles3P
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number of Protected Poles3
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit NC 10 A Auxiliary Circuit NO 6 A
Rated Operational Current AC-15 (Ie)(120 V) NC 3 A (120 V) NO 1.5 A (240 V) NC 3 A (240 V) NO 1.2 A (400 V) NC 0.75 A (400 V) NO 0.37 A (440 V) NC 0.75 A (440 V) NO 0.37 A (500 V) NC 0.3 A (500 V) NO 0.25 A
Rated Operational Current DC-13 (Ie)(125 V) NC 0.25 A (125 V) NO 0.25 A (24 V) NC 1.25 A (24 V) NO 1.25 A (250 V) NC 0.12 A (250 V) NO 0.04 A (60 V) NC 0.25 A (60 V) NO 0.25 A
Degree of ProtectionHousing IP20 Main Circuit Terminals IP00
Pollution Degree3
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Main CircuitHole Diameter > 10 mm² Rigid or Flexible with Cable Lug 1x 25 ... 120 mm²
Tightening TorqueAuxiliary Circuit 1 ... 1.3 N·m Main Circuit 25 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm
Recommended Screw DriverAuxiliary Circuit Pozidriv 1 Main Circuit Open Bars
Mounting Position1 ... 6
Power Lossat Rated Operating Conditions per Pole 3.8 ... 6.9 W
Suitable ForA145 A185 AF145 AF185 AF190 AF205
StandardsIEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Contact Rating UL/CSA(NC:) B600 (NO:) C600
Connecting Capacity Main Circuit UL/CSAFlexible 1x 4-0000 AWG Stranded 1x 4-0000 AWG
Connecting Capacity Auxiliary Circuit UL/CSAFlexible 1/2x 18-14 AWG Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 12 in·lb Main Circuit 220 in·lb
Ambient Air TemperatureOperation -25 ... +55 °C Operation Compensated -25 ... +55 °C Storage -40 ... +70 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 12g
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
ABB EcoSolutions Profile1SFC100125C0355
End Of Life Disassembling Instructions1SAC200335H0001
Environmental Information1SAC200056H0009
Environmental Product Declaration - EPD1SAC200275H0001
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 62.6 %
ABS Certificate1SAA941000-0102
BV Certificate1SAA941000-0201
CB Certificate1SAA941004-2003
CCC Certificate2024010304659820
CQC CertificateCQC2016010309922936
Declaration of Conformity - CCC2020980304001321
Declaration of Conformity - CE1SAD101100-3509
Declaration of Conformity - UKCA1SAD201100-3509
DNV Certificate1SAA941000-0304
DNV GL Certificate1SAA941000-0304
EAC Certificate1SAA941002-2702
GL Certificate1SAA941000-0304
LR Certificate1SAA941000-0504
RMRS Certificate1SAA941000-0704
UL CertificateE48139-19910930
Package Level 1 Unitsbox 1 piece
Package Level 1 Width165 mm
Package Level 1 Height133 mm
Package Level 1 Depth / Length151 mm
Package Level 1 Gross Weight1.02 kg
Package Level 1 EAN4013614286056
Package Level 2 Units4 piece
Package Level 2 Width280 mm
Package Level 2 Height210 mm
Package Level 2 Depth / Length395 mm
Package Level 2 Gross Weight8.786 kg
Package Level 2 EAN4013614494277
IDEA Granular Category Code (IGCC)5366 >> Thermal overload relay
E-Number (Finland)3709361
E-Number (Sweden)3228708

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.