AurFort
ABBTF140DU-135ABB TF140DU-135, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

THERMAL OVERLOAD RELAY

TF140DU-135

SKU 1SAZ431201R1003

ABB TF140DU-135: Thermal overload relay. Pole configuration: 3P.

3PPoles
TF140DU-135Product range
Thermal overload relayProduct type
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 09, 2026.

1SAZ431201R1003 — selected manufacturer specifications
Product ID1SAZ431201R1003
Catalog DescriptionTF140DU-135 Thermal Overload Relay 100 ... 135 A
Country of OriginIndia
Made To OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB015EXPU
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Data Sheet, Technical Information2CDC106061D0201
Instructions and Manuals2CDC106050M6802
Instructions and Manuals (Part 2)1SAC200017M0002
Time-Current Characteristic Curve1SAZ400503F0003
CAD Dimensional Drawing2CDC001079B0201
Dimension Diagram1SAZ400404F0001
Product Net Width89 mm
Product Net Height140 mm
Product Net Depth / Length126 mm
Product Net Weight0.82 kg
Setting Range100 ... 135 A
Rated Operational VoltageAuxiliary Circuit 440 V DC Auxiliary Circuit 500 V AC Main Circuit 690 V AC Main Circuit 440 V DC
Rated Operational Current (Ie)135 A
Rated Frequency (f)Auxiliary Circuit 50 Hz Auxiliary Circuit 60 Hz Auxiliary Circuit DC Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV Main Circuit 8 kV
Rated Insulation Voltage (Ui)690 V
Number of Poles3P
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number of Protected Poles3
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit NC 10 A Auxiliary Circuit NO 6 A
Rated Operational Current AC-15 (Ie)(120 V) NC 3 A (120 V) NO 1.5 A (240 V) NC 3 A (240 V) NO 1.2 A (400 V) NC 0.75 A (400 V) NO 0.37 A (440 V) NC 0.75 A (440 V) NO 0.37 A (500 V) NC 0.3 A (500 V) NO 0.25 A
Rated Operational Current DC-13 (Ie)(125 V) NC 0.25 A (125 V) NO 0.25 A (24 V) NC 1.25 A (24 V) NO 1.25 A (250 V) NC 0.12 A (250 V) NO 0.04 A (60 V) NC 0.25 A (60 V) NO 0.25 A
Degree of ProtectionIP20 Housing IP20 Main Circuit Terminals IP10
Pollution Degree3
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 16 ... 70 mm² Flexible with Insulated Ferrule 1/2x 16 ... 70 mm² Flexible 1/2x 16 ... 70 mm² Rigid 1/2x 16 ... 70 mm²
Tightening TorqueAuxiliary Circuit 0.8 ... 1.2 N·m Main Circuit 8 ... 10 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm Main Circuit 25 mm
Recommended Screw DriverAuxiliary Circuit Pozidriv 2 Main Circuit Hexagon 4
Mounting Positionany
Power Lossat Rated Operating Conditions per Pole 2.3 W
Suitable ForAF116 AF140
StandardsIEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Contact Rating UL/CSA(NC:) B600 (NO:) C300
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 6-2/0 AWG Stranded 1/2x 6-2/0 AWG
Connecting Capacity Auxiliary Circuit UL/CSAFlexible 1/2x 18-14 AWG Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 12 in·lb
Ambient Air TemperatureOperation -25 ... +55 °C Operation Compensated -25 ... +55 °C Storage -40 ... +70 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 12g 25g 2 shocks 13 ms
Resistance to Vibrations20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
ABB EcoSolutions Profile1SFC100125C0355
End Of Life Disassembling Instructions1SAC200334H0001
Environmental Information1SAC200090H0009
Environmental Product Declaration - EPD1SAC200274H0001
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 61.1 %
ABS Certificate1SAA941004-0101
BV Certificate1SAA941003-0201
CB Certificate1SAA941012-2001
CCC Certificate2024010304659821
CQC CertificateCQC2016010309922935
Declaration of Conformity - CCC2020980304001320
Declaration of Conformity - CE1SAD101100-3507
Declaration of Conformity - UKCA1SAD201100-3507
DNV GL Certificate1SAA941004-0301
EAC Certificate1SAA941002-2702
LR Certificate1SAA941004-0501
RINA CertificateRINA_ELE098115XG
RMRS Certificate1SAA941002-0701
UL CertificateE48139-20120831
Package Level 1 Unitscarton 1 piece
Package Level 1 Width165 mm
Package Level 1 Height133 mm
Package Level 1 Depth / Length151 mm
Package Level 1 Gross Weight0.945 kg
Package Level 1 EAN4013614446832
Package Level 2 Units4 piece
Package Level 2 Width280 mm
Package Level 2 Height210 mm
Package Level 2 Depth / Length395 mm
Package Level 2 Gross Weight8.786 kg
Package Level 2 EAN4013614494376
IDEA Granular Category Code (IGCC)5366 >> Thermal overload relay
E-Number (Finland)3706578
E-Number (Norway)4116773
E-Number (Sweden)3210243

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.