SKU 1SBE111111R0611ABB ESB16-11N-06: Installation contactor for distribution board. Pole configuration: 2P.
2PPoles
ESB16-11N-06Product range
Installation contactor for distribution boardProduct type
PRODUCT DATA
Technical specifications
Source: ABB English regional product catalog.
Verified September 08, 2026.
| Product ID | 1SBE111111R0611 |
|---|---|
| Catalog Description | ESB16-11N-06 Installation Contactor (NC) 16 A - 1 NO - 1 NC - 230 V - Control Circuit DC |
| Country of Origin | India |
| Made To Order | No |
| Warranty Return | Product under warranty must be returned |
| Product Sales Status | Active |
| Quote Only | No |
| Stocked At Warehouses | INABB015EXPU |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| EPLAN Data | 9AAC404713_EPLAN |
| Data Sheet, Technical Information | 2CDC103051C0201 |
| Instructions and Manuals | 2CDC103043M6801 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Product Net Width | 18 mm |
| Product Net Depth / Length | 65 mm |
| Product Net Height | 85 mm |
| Product Net Weight | 0.14 kg |
| Dimension Diagram | 1SBB505186D3001 |
| Number of Main Contacts NO | 1 |
| Number of Main Contacts NC | 1 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 2P |
| Standards | IEC/EN 60947-1 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1 IEC/EN 61095 IEC 60335-2-40 A2L |
| Rated Operational Voltage | Main Circuit 220 V DC Main Circuit 240 V AC |
| Rated Frequency (f) | Control Circuit DC Control Circuit 50 Hz Control Circuit 60 Hz Control Circuit 400 Hz Main Circuit DC Main Circuit 50 Hz Main Circuit 60 Hz |
| Rated Operational Current AC-1 (Ie) | (NC) 16 A (NO) 16 A |
| Rated Operational Current AC-3 (Ie) | (230 V) Single Phase, NC 6 A (230 V) Single Phase, NO 6 A |
| Rated Operational Current AC-7a (Ie) | (NC) 16 A (NO) 16 A |
| Rated Operational Current AC-7b (Ie) | (230 V) Single Phase, NC 6 A (230 V) Single Phase, NO 6 A |
| Rated Operational Power AC-1 (Pe) | (230 V) Single Phase, NC 3.7 kW (230 V) Single Phase, NO 3.7 kW |
| Rated Operational Power AC-3 (Pe) | (230 V) Single Phase, NC 0.9 kW (230 V) Single Phase, NO 0.9 kW |
| Rated Operational Power AC-7a (Pe) | (230 V) Single Phase, NC 3.7 kW (230 V) Single Phase, NO 3.7 kW |
| Rated Operational Power AC-7b (Pe) | (230 V) Single Phase, NC 0.9 kW (230 V) Single Phase, NO 0.9 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A |
| Rated Insulation Voltage (Ui) | 400 V |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Electrical Durability | AC-1 (NC) 150000 cycle AC-1 (NO) 150000 cycle AC-3 (NC) 150000 cycle AC-3 (NO) 150000 cycle AC-7a (NC) 150000 cycle AC-7a (NO) 150000 cycle AC-7b (NC) 150000 cycle AC-7b (NO) 150000 cycle |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour (AC-3) 600 cycles per hour (AC-7a) 300 cycles per hour (AC-7b) 600 cycles per hour |
| Mechanical Durability | Nr. Operations 1000000 cycle |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (Uc) | 230 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 2.5 V·A Average Holding Value DC 2.5 W Average Pull-in Value 50 Hz 2.5 V·A Average Pull-in Value 60 Hz 2.5 V·A Average Pull-in Value DC 2.5 W |
| Power Loss | at Rated Operating Conditions AC-1 per Pole NC 0.9 W at Rated Operating Conditions AC-1 per Pole NO 0.9 W |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1x 1 ... 6 mm² Flexible with Ferrule 2x 1 ... 2.5 mm² Flexible with Insulated Ferrule 1x 1 ... 6 mm² Flexible with Insulated Ferrule 2x 1 ... 1.5 mm² Flexible 1x 1 ... 6 mm² Flexible 2x 1 ... 4 mm² Rigid 1x 1 ... 10 mm² Rigid 2x 1 ... 4 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm² Flexible with Ferrule 2x 0.75 ... 1.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1 mm² Flexible 1x 1 ... 2.5 mm² Flexible 2x 1 ... 1.5 mm² Rigid 1x 0.5 ... 4 mm² Rigid 2x 0.75 ... 2.5 mm² |
| Wire Stripping Length | Control Circuit 7 mm Main Circuit 10 mm |
| Degree of Protection | IP20 |
| Recommended Screw Driver | Control Circuit Pozidriv 1 Main Circuit Pozidriv 1 |
| Tightening Torque | Control Circuit 0.9 N·m Main Circuit 1.2 N·m |
| Terminal Type | Screw Terminals |
| Width in Number of Modular Spacings | 1 |
| Product Name | Installation Contactor |
| Maximum Operating Voltage UL/CSA | Main Circuit 240 V AC |
| General Use Rating UL/CSA | (acc. to UL 240 V) 16 A |
| Horsepower Rating UL/CSA | (220 ... 240 V AC) Single Phase, NC 0.75 Hp (220 ... 240 V AC) Single Phase, NO 0.75 Hp |
| Connecting Capacity Main Circuit UL/CSA | Solid 14-8 AWG Stranded 14-8 AWG |
| Connecting Capacity Control Circuit UL/CSA | Solid 16-10 AWG Stranded 16-10 AWG |
| Tightening Torque UL/CSA | Control Circuit 8 in·lb Main Circuit 11 in·lb |
| Full Load Amps Motor Use | (220 ... 240 V AC) Single Phase, NC 6.9 A (220 ... 240 V AC) Single Phase, NO 6.9 A |
| Ambient Air Temperature | Operation -25 ... +55 °C Storage -40 ... +80 °C |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g |
| Pollution Degree | 3 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| ABB EcoSolutions Profile | 1SFC100125C0336 |
| End Of Life Disassembling Instructions | 1SBC100156C0268 |
| Environmental Product Declaration - EPD | 1SAC200416H0001 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 87.4 % |
| A2L Certificate – IEC | 1SAA920000-4601 |
| ABS Certificate | 1SAA920000-0101 |
| CB Certificate | 1SAA920007-2001 |
| CCC Certificate | 2024010304659814 2024010304659813 |
| Declaration of Conformity - CE | 1SAD101100-3301 |
| Declaration of Conformity - UKCA | 1SAD201100-3301 |
| DNV Certificate | 1SAA920000-0306 |
| UL Certificate | E191658-19960301 |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 88 mm |
| Package Level 1 Depth / Length | 20 mm |
| Package Level 1 Height | 71 mm |
| Package Level 1 Gross Weight | 0.14 kg |
| Package Level 1 EAN | 3471523004474 |
| Package Level 2 EAN | 4013614583414 |
| IDEA Granular Category Code (IGCC) | 4759 >> Installation contactor for distribution board |
| E-Number (Finland) | 3707563 |
| E-Number (Sweden) | 3210554 |