AurFort
ABBAF40-40-00-11ABB AF40-40-00-11, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

POWER CONTACTOR, AC SWITCHING

AF40-40-00-11

SKU 1SBL347201R1100

ABB AF40-40-00-11: Power contactor, AC switching. Pole configuration: 4P.

4PPoles
AF40-40-00-11Product range
Power contactor, AC switchingProduct type
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 09, 2026.

1SBL347201R1100 — selected manufacturer specifications
Product ID1SBL347201R1100
Catalog DescriptionAF40-40-00-11 24-60V50/60HZ 20-60VDC Contactor
Country of OriginIndia
Made To OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB015EXPU
Minimum Order Quantity1 piece
Customs Tariff Number85364900
EPLAN Data9AAC175972_EPLAN
Data Sheet, Technical Information1SBC100214C0202
Instructions and Manuals1SBC101047M6801
Instructions and Manuals (Part 2)1SAC200017M0002
CAD Dimensional Drawing2CDC001079B0201
Product Net Width70 mm
Product Net Depth / Length113.5 mm
Product Net Height125.5 mm
Product Net Weight1.21 kg
Number of Main Contacts NO4
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Number of Poles4P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 70 A (690 V) 60 °C 60 A (690 V) 70 °C 50 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 40 A (440 V) 60 °C 40 A (500 V) 60 °C 35 A (690 V) 60 °C 25 A (380 / 400 V) 60 °C 40 A (220 / 230 / 240 V) 60 °C 40 A
Rated Operational Power AC-3 (Pe)(415 V) 22 kW (440 V) 22 kW (500 V) 22 kW (690 V) 22 kW (380 / 400 V) 18.5 kW (220 / 230 / 240 V) 11 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 4 V·A Average Holding Value 50 Hz 4 V·A Average Holding Value 60 Hz 4 V·A Average Holding Value DC 2 W Average Holding Value, from Warm State 2 W
Power Lossat Rated Operating Conditions AC-1 per Pole 3 W at Rated Operating Conditions AC-3 per Pole 1 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 4 ... 35 mm² Flexible with Insulated Ferrule 1/2x 4 ... 35 mm² Rigid Stranded 1/2x 6 ... 35 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthControl Circuit 10 mm Main Circuit 16 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw DriverPozidriv PZ
Tightening TorqueControl Circuit 1.2 N·m Main Circuit 4 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 60 A
Connecting Capacity Main Circuit UL/CSARigid Stranded 1/2x 10-2 AWG
Connecting Capacity Control Circuit UL/CSARigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAControl Circuit 11 in·lb Main Circuit 35 in·lb
Full Load Amps Motor Use(120 V AC) Single Phase 3 A (200 ... 208 V AC) Three Phase 10 A (220 ... 240 V AC) Three Phase 15 A (240 V AC) Single Phase 7-1/2 A (440 ... 480 V AC) Three Phase 30 A (550 ... 600 V AC) Three Phase 40 A
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Vibrations3g Closed Position & 2g Open Position 5 ... 300 Hz
Pollution Degree3
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP5119a3b5-1f1f-4c94-abc3-493b30c8442a China
Simplified SCIP00da5959-06fd-47e9-affa-9f2e448a908c Denmark 057e78bb-ff57-43e6-9e79-891d7748e9b0 Netherlands 059ccf7f-7042-4935-b54d-00e8d364c33b Czechia 0f449076-bc8f-48b4-b083-ca23a5401582 Romania 31d3969b-f968-4f0e-904d-0ed253f32a8a Germany 45b3c271-48a0-4a0d-9f1e-dfdf3058802f Poland 57dfc049-e3cd-4324-8904-d54f9d425179 Hungary 5c833bd8-24ef-425a-bd02-86195926ffe8 Croatia 69e8badc-e36e-45af-bfca-3238a3e11c6d Norway 7c10bca8-33de-4453-8bfe-85fe879126c3 Greece 7e94b652-ac42-484e-86e2-5bf2f764059f Portugal 7f78c88e-ef17-471c-b29c-811940b706ec Estonia 90f36764-1421-457b-bf48-c32b429b28d5 Finland 99f63080-c6dd-4917-b274-7775bad00550 France c68ca4ca-a878-44ac-be34-c91ca9c48978 Sweden c6aa0a6c-ff9d-4a0a-9607-869251bd0756 Spain c9fbf7ff-e97c-4d6b-9b9c-9bdd523f3751 Bulgaria ff15a6fe-9744-4a2a-9e68-e160750882ad Belgium
Toxic Substances Control Act - TSCA2CMT2023-006525
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
ABB EcoSolutions Profile1SBC100156C0308
End Of Life Disassembling Instructions1SBC101081M6801
Environmental Product Declaration - EPD1SBD250584E1000
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 91.9 %
A2L Certificate – UL9AKK108469A4890 9AKK108469A4892
ABS CertificateABS_26-0348269-PDA_FR ABS_26-0348269-PDA-DUP_CN
BV CertificateBV_2634H36994C0
CB CertificateSE-115941
CCC CertificateCCC_2024010304648524
Declaration of Conformity - CCC2020980304001256
Declaration of Conformity - CE1SBD250001U1000
Declaration of Conformity - UKCA1SBD250032U1000
DNV CertificateTAE00001AF-5
LR CertificateLRS_LR23403517TA-02
RMRS CertificateRMRS_1400682124
UL CertificateUL-US-L312527-1142-02114102-12 UL-CA-L312527-4142-02114102-12
UL Listing CardUL_E312527
Package Level 1 Unitsbox 1 piece
Package Level 1 Width150 mm
Package Level 1 Depth / Length150 mm
Package Level 1 Height103 mm
Package Level 1 Gross Weight1.32 kg
Package Level 1 EAN3471523133518
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
E-Number (Finland)3707255
E-Number (Sweden)3210296

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.