ABBAF80-40-00-11

ABB catalog image for this SKU; may represent the product family.
POWER CONTACTOR, AC SWITCHING
AF80-40-00-11
SKU 1SBL397201R1100ABB AF80-40-00-11: Power contactor, AC switching. Pole configuration: 4P.
4PPoles
AF80-40-00-11Product range
Power contactor, AC switchingProduct type
PRODUCT DATA
Technical specifications
Source: ABB English regional product catalog.
Verified September 09, 2026.
| Product ID | 1SBL397201R1100 |
|---|---|
| Catalog Description | AF80-40-00-11 24-60V50/60HZ 20-60VDC Contactor |
| Country of Origin | India |
| Made To Order | No |
| Warranty Return | Product under warranty must be returned |
| Product Sales Status | Active |
| Quote Only | No |
| Stocked At Warehouses | INABB015EXPU |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| EPLAN Data | 9AAC175975_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 1SBC101047M6801 |
| Instructions and Manuals (Part 2) | 1SAC200017M0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Product Net Width | 90 mm |
| Product Net Depth / Length | 116 mm |
| Product Net Height | 125.5 mm |
| Product Net Weight | 1.49 kg |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22 |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 125 A (690 V) 60 °C 105 A (690 V) 70 °C 90 A |
| Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 80 A (440 V) 60 °C 80 A (500 V) 60 °C 65 A (690 V) 60 °C 49 A (1000 V) 60 °C 25 A (380 / 400 V) 60 °C 80 A (220 / 230 / 240 V) 60 °C 80 A |
| Rated Operational Power AC-3 (Pe) | (415 V) 45 kW (440 V) 45 kW (500 V) 45 kW (690 V) 45 kW (1000 V) 35 kW (380 / 400 V) 37 kW (220 / 230 / 240 V) 22 kW |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 1000 V acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc) | 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 4 V·A Average Holding Value 50 Hz 4 V·A Average Holding Value 60 Hz 4 V·A Average Holding Value DC 2 W Average Holding Value, from Warm State 2 W |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 8 W at Rated Operating Conditions AC-3 per Pole 3.2 W |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) | 2 x M4 or 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 6 ... 50 mm² Flexible with Insulated Ferrule 1/2x 6 ... 50 mm² Rigid Stranded 1x 6 ... 70 mm² Rigid Stranded 2x 6 ... 50 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm² |
| Wire Stripping Length | Control Circuit 10 mm Main Circuit 17 mm |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10 |
| Recommended Screw Driver | Pozidriv PZ |
| Tightening Torque | Control Circuit 1.2 N·m Main Circuit 6 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 105 A |
| Connecting Capacity Main Circuit UL/CSA | Rigid Stranded 1/2x 6-1 AWG |
| Connecting Capacity Control Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG |
| Tightening Torque UL/CSA | Control Circuit 11 in·lb Main Circuit 53 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 7-1/2 A (200 ... 208 V AC) Three Phase 25 A (220 ... 240 V AC) Three Phase 30 A (240 V AC) Single Phase 15 A (440 ... 480 V AC) Three Phase 60 A (550 ... 600 V AC) Three Phase 75 A |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Vibrations | 3g Closed Position & 2g Open Position 5 ... 300 Hz |
| Pollution Degree | 3 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 68d4c68e-2933-49f3-8d99-9153a7f4eac0 France |
| Simplified SCIP | 010293b0-d0c6-4c19-ae49-35290d3fdc27 Czechia 060f08fd-2df5-4db8-99bf-5ead76502dcd Hungary 0ac8f3ae-7dff-4c87-a8b7-72c5d850ff01 Sweden 115e2c98-4fda-4194-9b0f-6e13af7aba3f Romania 19152b87-0138-4c48-9cc2-3acf15cf5f72 Germany 249e4303-db10-474d-bc51-8f2ec53ea623 Netherlands 2763def7-3e5b-4e86-a3bc-19a1212c7a77 Denmark 3387db51-8369-45ac-9cd9-d07a465bb507 Germany 39956474-f1e3-43fe-82eb-65c0b0fa8260 Croatia 41256d37-19e7-43dd-ab77-b28479fbd5df Spain 475c8df0-81ab-4e7d-968f-01ce76235c02 France 5c57483d-0176-4c4e-a1ae-0341f51c318e Belgium 647703b1-52fd-4974-a17c-6e05678f280b Belgium 6a98020b-be8b-443c-8c68-69a85a920b8b Poland 6e699e21-3062-4bc8-98a5-6fc26fa4c09c Sweden 719a3341-a932-4880-a038-5d3c52587ac8 Estonia 7672be41-dea1-4bf5-a76a-2947e7a56e86 Poland 8048198a-8399-492e-9ae4-b8f462654ac2 Greece 9524d187-e354-4105-adb5-05d4c4109547 Norway 960ff7fa-f8ac-4f5f-813e-26a4715f8f3b Poland b7eee56c-e225-4f18-8fb4-09bab452a6d6 Finland c10b3b3f-ee1e-4b47-92a2-d109b2f7586d Italy c4f50c0d-e1ca-4bf4-820e-1415efd770ec Germany c5226ee5-3491-4ea8-aab5-022ea0ba1527 Hungary cd47605f-5f03-4582-acf3-28dca92405dc Germany dc2ef974-978f-463b-83c4-99df2c2b8e15 Germany e0e23321-97ad-4e03-b974-5f75b61db37a Portugal f1404899-9eac-430a-be0b-b89a897dedf8 Bulgaria |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| ABB EcoSolutions Profile | 1SBC100156C0308 |
| End Of Life Disassembling Instructions | 1SBC101081M6801 |
| Environmental Product Declaration - EPD | 1SBD250584E2000 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 91.9 % |
| A2L Certificate – UL | 9AKK108469A4890 9AKK108469A4892 |
| ABS Certificate | ABS_26-0348269-PDA_FR ABS_26-0348269-PDA-DUP_CN |
| BV Certificate | BV_2634H36994C0 |
| CB Certificate | CB_SE-116522A2 |
| CCC Certificate | CCC_2024010304656667 |
| Declaration of Conformity - CCC | 2020980304001255 |
| Declaration of Conformity - CE | 1SBD250001U1000 |
| Declaration of Conformity - UKCA | 1SBD250032U1000 |
| DNV Certificate | TAE00001AF-5 |
| LR Certificate | LRS_LR23403517TA-02 |
| RMRS Certificate | RMRS_1400682124 |
| UL Certificate | UL-US-L312527-1142-02114102-12 UL-CA-L312527-4142-02114102-12 |
| UL Listing Card | UL_E312527 |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 150 mm |
| Package Level 1 Depth / Length | 150 mm |
| Package Level 1 Height | 103 mm |
| Package Level 1 Gross Weight | 1.62 kg |
| Package Level 1 EAN | 3471523133716 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| E-Number (Finland) | 3707458 |
| E-Number (Sweden) | 3210313 |
For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.