AurFort
ABBCAT4-11EABB CAT4-11E, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

AUXILIARY CONTACT BLOCK

CAT4-11E

SKU 1SBN010151R1011

ABB CAT4-11E: Auxiliary contact block. Pole configuration: 2P.

2PPoles
CAT4-11EProduct range
Auxiliary contact blockProduct type
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 09, 2026.

1SBN010151R1011 — selected manufacturer specifications
Product ID1SBN010151R1011
Catalog DescriptionCAT4-11E Auxiliary Contact / Coil Terminal Block
Configuration OnlyNo
Country of OriginPoland
CriticalityNo
Lead Time18 day 0 day 35 day
Made To OrderNo
NoteNo
Product Availability ClassStandard delivery time
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesBRAPR001EXPU CHNOR001EXPU CLABB001EXPU CNIAB001EXPU COABB001EXPU DEAPRMLCEXPU DKSER001EXPU DUABB001EXPU DUABB003EXPU EESER001EXPU EGAUT001EXPU ESATD001EXPU FISER001EXPU FRAUT001EXPU GBINS001EXPU GRABB001EXPU INABB039EXPU INABBRLCEXPU ITIND002EXPU NLABB021EXPU NOATDRLCEXPU SGIND002EXPU TRDMD001EXPU USABB251EXPU USSVCEXPU ZATAD021EXPU
Storage Location4001
Warranty ReturnProduct under warranty must be returned
Technical InformationAF26...65-30-, AF09…52-40-, AF09…40-22-
Minimum Order Quantity1 piece
Customs Tariff Number85389099
Data Sheet, Technical Information1SBC100214C0202
Instructions and Manuals1SBC101041M6801
Instructions and Manuals (Part 2)1SAC200017M0002
CAD Dimensional Drawing2CDC001079B0201
Product Net Width45 mm
Product Net Depth / Length31.6 mm
Product Net Height43 mm
Product Net Weight0.04 kg
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles2P
StandardsIEC/EN 60947-5-1, UL 60335-2-40 LZGH2 A2L, UL 60947-5-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-5-1-14
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A for 1 s 100 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm Control Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Tightening TorqueAuxiliary Circuit 1.2 N·m Control Circuit 1.2 N·m
Terminal TypeScrew Terminals
Suitable ForAF09 AF09Z AF12 AF12Z AF16 AF16Z AF26 AF26Z AF30 AF30Z AF38 AF38Z AF40 AF52 AF65 AFC09 AFC12 AFC16 AFC26 AFC30 AFC38 AFC40 AFC52 AFC65 AFC80 AFC96 AF09B AF09ZB AF12B AF12ZB AF16B AF16ZB AF26B AF26ZB AF30B AF30ZB AF38B AF38ZB AF40B AF52B AF65B AF80B AF96B
Product NameAuxiliary Contact and Coil Terminal Block
Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSARigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb Control Circuit 11 in·lb
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
A2L Certificate – UL9AKK108469A4897 9AKK108469A4898
ABS CertificateABS_26-0348269-PDA_FR
BV CertificateBV_2634H24900C1
CB CertificateSE-118824
CQC CertificateCQC2013010304651497
Declaration of Conformity - CCC2020980304001259
Declaration of Conformity - CE1SBD250007U1000
Declaration of Conformity - UKCA1SBD250038U1000
DNV CertificateDNV_TAE00001BV-6
LR CertificateLRS_LR23403517TA-02
RINA CertificateRINA_ELE084013XG
RMRS CertificateRMRS_1802703280
UL CertificateUL-US-L252354-131-82119002-7 UL-CA-L252354-331-82119002-6
UL Listing CardUL_E252354
Package Level 1 Unitsbox 1 piece
Package Level 1 Width46 mm
Package Level 1 Depth / Length46 mm
Package Level 1 Height46 mm
Package Level 1 Gross Weight0.04 kg
Package Level 1 EAN3471523130067
Package Level 2 Unitsbox 192 piece
Package Level 2 Gross Weight7.68 kg
IDEA Granular Category Code (IGCC)4743 >> Auxiliary contact block
E-Number (Finland)3706508
E-Number (Sweden)3211430

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.