ABBCAT4-11E

ABB catalog image for this SKU; may represent the product family.
AUXILIARY CONTACT BLOCK
CAT4-11E
SKU 1SBN010151R1011ABB CAT4-11E: Auxiliary contact block. Pole configuration: 2P.
2PPoles
CAT4-11EProduct range
Auxiliary contact blockProduct type
PRODUCT DATA
Technical specifications
Source: ABB English regional product catalog.
Verified September 09, 2026.
| Product ID | 1SBN010151R1011 |
|---|---|
| Catalog Description | CAT4-11E Auxiliary Contact / Coil Terminal Block |
| Configuration Only | No |
| Country of Origin | Poland |
| Criticality | No |
| Lead Time | 18 day 0 day 35 day |
| Made To Order | No |
| Note | No |
| Product Availability Class | Standard delivery time |
| Product Sales Status | Active |
| Quote Only | No |
| Stocked At Warehouses | BRAPR001EXPU CHNOR001EXPU CLABB001EXPU CNIAB001EXPU COABB001EXPU DEAPRMLCEXPU DKSER001EXPU DUABB001EXPU DUABB003EXPU EESER001EXPU EGAUT001EXPU ESATD001EXPU FISER001EXPU FRAUT001EXPU GBINS001EXPU GRABB001EXPU INABB039EXPU INABBRLCEXPU ITIND002EXPU NLABB021EXPU NOATDRLCEXPU SGIND002EXPU TRDMD001EXPU USABB251EXPU USSVCEXPU ZATAD021EXPU |
| Storage Location | 4001 |
| Warranty Return | Product under warranty must be returned |
| Technical Information | AF26...65-30-, AF09…52-40-, AF09…40-22- |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85389099 |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 1SBC101041M6801 |
| Instructions and Manuals (Part 2) | 1SAC200017M0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 31.6 mm |
| Product Net Height | 43 mm |
| Product Net Weight | 0.04 kg |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 2P |
| Standards | IEC/EN 60947-5-1, UL 60335-2-40 LZGH2 A2L, UL 60947-5-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-5-1-14 |
| Rated Operational Voltage | Auxiliary Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-15 (Ie) | (500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (400 / 440 V) 3 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 140 A for 1 s 100 A |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-5-1 690 V acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm² |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm² |
| Wire Stripping Length | Auxiliary Circuit 10 mm Control Circuit 10 mm |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1.2 N·m Control Circuit 1.2 N·m |
| Terminal Type | Screw Terminals |
| Suitable For | AF09 AF09Z AF12 AF12Z AF16 AF16Z AF26 AF26Z AF30 AF30Z AF38 AF38Z AF40 AF52 AF65 AFC09 AFC12 AFC16 AFC26 AFC30 AFC38 AFC40 AFC52 AFC65 AFC80 AFC96 AF09B AF09ZB AF12B AF12ZB AF16B AF16ZB AF26B AF26ZB AF30B AF30ZB AF38B AF38ZB AF40B AF52B AF65B AF80B AF96B |
| Product Name | Auxiliary Contact and Coil Terminal Block |
| Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG |
| Connecting Capacity Control Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG |
| Tightening Torque UL/CSA | Auxiliary Circuit 11 in·lb Control Circuit 11 in·lb |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| A2L Certificate – UL | 9AKK108469A4897 9AKK108469A4898 |
| ABS Certificate | ABS_26-0348269-PDA_FR |
| BV Certificate | BV_2634H24900C1 |
| CB Certificate | SE-118824 |
| CQC Certificate | CQC2013010304651497 |
| Declaration of Conformity - CCC | 2020980304001259 |
| Declaration of Conformity - CE | 1SBD250007U1000 |
| Declaration of Conformity - UKCA | 1SBD250038U1000 |
| DNV Certificate | DNV_TAE00001BV-6 |
| LR Certificate | LRS_LR23403517TA-02 |
| RINA Certificate | RINA_ELE084013XG |
| RMRS Certificate | RMRS_1802703280 |
| UL Certificate | UL-US-L252354-131-82119002-7 UL-CA-L252354-331-82119002-6 |
| UL Listing Card | UL_E252354 |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 46 mm |
| Package Level 1 Depth / Length | 46 mm |
| Package Level 1 Height | 46 mm |
| Package Level 1 Gross Weight | 0.04 kg |
| Package Level 1 EAN | 3471523130067 |
| Package Level 2 Units | box 192 piece |
| Package Level 2 Gross Weight | 7.68 kg |
| IDEA Granular Category Code (IGCC) | 4743 >> Auxiliary contact block |
| E-Number (Finland) | 3706508 |
| E-Number (Sweden) | 3211430 |