AurFort
ABBAF265-30-11-11ABB AF265-30-11-11, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

POWER CONTACTOR, AC SWITCHING

AF265-30-11-11

SKU 1SFL547002R1111

ABB AF265-30-11-11: Power contactor, AC switching. Pole configuration: 3P.

3PPoles
AF265-30-11-11Product range
Power contactor, AC switchingProduct type
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 08, 2026.

1SFL547002R1111 — selected manufacturer specifications
Product ID1SFL547002R1111
Catalog DescriptionAF265-30-11-11 Contactor
Country of OriginIndia
Lead Time0 day
Made To OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesAETAD009EXPU BRABB008EXPU CHSEC006EXPU INABB003EXPU INABB015EXPU
Minimum Order Quantity1 piece
Customs Tariff Number85364900
EPLAN Data9AAC175202_EPLAN
Data Sheet, Technical Information1SBC100214C0202
Data Sheet, Technical Information (Part 2)1SAC200017M0002
Instructions and Manuals1SFC100008M0201
CAD Dimensional Drawing2CDC001079B0201
Product Net Width140 mm
Product Net Depth / Length180 mm
Product Net Height225 mm
Product Net Weight3.9 kg
Dimension Diagram1SFB535001G1060
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles3P
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 350 A (1000 V) 55 °C 300 A (1000 V) 60 °C 300 A (1000 V) 70 °C 240 A (690 V) 40 °C 400 A (690 V) 55 °C 350 A (690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 265 A (440 V) 55 °C 265 A (500 V) 55 °C 250 A (690 V) 55 °C 250 A (1000 V) 55 °C 113 A (380 / 400 V) 55 °C 265 A (220 / 230 / 240 V) 55 °C 265 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 350 A (220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 350 A (220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 350 A (220 V) 3 Poles in Series, 40 °C 350 A
Rated Operational Power AC-3 (Pe)(415 V) 132 kW (440 V) 160 kW (500 V) 160 kW (690 V) 200 kW (1000 V) 160 kW (380 / 400 V) 132 kW (220 / 230 / 240 V) 75 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Breaking Capacity AC-3e8.5 x Ie AC-3e
Rated Making Capacity AC-310 x Ie AC-3
Rated Making Capacity AC-3e12 x Ie AC-3e
Short-Circuit Protective DevicesgG Type Fuses 500 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1224 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2120 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 865 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3800 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3300 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour (AC-2 / AC-4) 150 cycles per hour (AC-3) 300 cycles per hour
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V·A Holding at Max. Rated Control Circuit Voltage DC 2.9 V·A Holding at Max. Rated Control Circuit Voltage DC 2.9 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 695 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 695 V·A Pull-in at Max. Rated Control Circuit Voltage DC 980 V·A Pull-in at Max. Rated Control Circuit Voltage DC 980 W
Power Lossat Rated Operating Conditions AC-1 per Pole 20 W at Rated Operating Conditions AC-3 per Pole 9 W
Operate TimeBetween Coil De-energization and NO Contact Opening 37 ... 47 ms Between Coil Energization and NO Contact Closing 25 ... 55 ms
Connecting Capacity Main CircuitFlexible 2 x 70 ... 185 mm² Rigid Al-Cable 1 x 185 ... 240 mm² Rigid Cu-Cable 2 x 70 ... 185 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 2x0.75 ... 2.5 mm² Solid 2 x 1 ... 4 mm² Stranded 1 x 1 .... 4 mm² Stranded 2 x 1 .... 4 mm²
Connecting CapacityFlexible 2 x 70 ... 185 mm² Rigid Al-Cable 1 x 185 ... 240 mm² Rigid Cu-Cable 2 x 70 ... 185 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening TorqueCable Lug 9 N·m Main Circuit 22 ... 43 N·m
Terminal TypeMain Circuit: Bars
Product NameBlock Contactor
NEMA Size5
Continuous Current Rating NEMA270 A
Horsepower Rating NEMA(200 V AC) Three Phase 75 Hp (230 V AC) Three Phase 100 Hp (460 V AC) Three Phase 200 Hp (575 V AC) Three Phase 200 Hp
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(1000 V AC) 300 A (600 V AC) 350 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 75 hp (208 V AC) Three Phase 75 hp (220 ... 240 V AC) Three Phase 100 hp (440 ... 480 V AC) Three Phase 200 hp (550 ... 600 V AC) Three Phase 250 hp
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 240 A (550 ... 600 V AC) Three Phase 242 A
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNon-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
ABB EcoSolutions Profile1SFC100125C0366
End Of Life Disassembling Instructions1SFC100112M0002
Environmental Product Declaration - EPD1SFC100104D0201 2TFP200030A1001
Extended Product LifetimeProduct Durability is Enhanced
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)Recycled Metal - 33 %
A2L Certificate – UL9AKK108468A6695
ABS Certificate14-LD1092198-PDA 14-LD1092198-1-PDA-DUP
BV CertificateBV_36353_A0BV
CB CertificateSE-89316
CCS CertificateGB14T00030 GZ15T00069
CQC CertificateCQC2014010304676670 CQC2014010304673866
cULus Certificate20121217-E36588
Declaration of Conformity - CE2CMT2015-005439
Declaration of Conformity - UKCA2CMT2020-006118
DNV CertificateDNV_E-14043
LR Certificate16-20064
PRS CertificateTE_2092_880423_16
RINA CertificateELE060313XG_002
UL Listing CardUL_E36588
Package Level 1 Unitsbox 1 piece
Package Level 1 Width263 mm
Package Level 1 Depth / Length203 mm
Package Level 1 Height289 mm
Package Level 1 Gross Weight4.6 kg
Package Level 1 EAN7320500481141
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
E-Number (Finland)3706468
E-Number (Norway)4117647
E-Number (Sweden)3210153

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.