AurFort
ABBAF580-30-11-70ABB AF580-30-11-70, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

POWER CONTACTOR, AC SWITCHING

AF580-30-11-70

SKU 1SFL617001R7011

ABB AF580-30-11-70: Power contactor, AC switching. Pole configuration: 3P.

3PPoles
AF580-30-11-70Product range
Power contactor, AC switchingProduct type
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 08, 2026.

1SFL617001R7011 — selected manufacturer specifications
Product ID1SFL617001R7011
Catalog DescriptionAF580-30-11 100-250V 50/60Hz / 100-250V DC Contactor
Configuration OnlyNo
Country of OriginSweden China India United States
CriticalityNo
Lead Time999 day 28 day 0 day 26 day
Made To OrderNo
NoteNo
Product Availability ClassNo more available. No replacement Price is valid until the current stock lasts. This item belongs to a product which is in the obsolete phase and no longer available. Please contact local product sales in order to find a replacing product
Product Sales StatusInactive Active
Quote OnlyNo
Replacement Part ID64399756
Storage Location4001
Warranty ReturnProduct under warranty must be returned
Stocked At WarehousesINABB015EXPU USABB251EXPU USSVCEXPU
Minimum Order Quantity1 piece
Customs Tariff Number85364900
EPLAN Data9AAC200768_EPLAN
Data Sheet, Technical Information1SBC100214C0202
Data Sheet, Technical Information (Part 2)1SAC200017M0002
Instructions and Manuals1SFC380023-en
CAD Dimensional Drawing2CDC001079B0201
Product Net Width210 mm
Product Net Depth / Length242 mm
Product Net Height283 mm
Product Net Weight13.6 kg
Dimension Diagram53540919-60
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles3P
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 800 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 800 A (1000 V) 55 °C 700 A (1000 V) 70 °C 580 A (690 V) 40 °C 800 A (690 V) 55 °C 700 A (690 V) 70 °C 580 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 580 A (440 V) 55 °C 580 A (500 V) 55 °C 580 A (690 V) 55 °C 500 A (1000 V) 55 °C 250 A (380 / 400 V) 55 °C 580 A (220 / 230 / 240 V) 55 °C 580 A
Rated Operational Current DC-1 (Ie)(110 V) 1-Pole, 40 °C 800 A (110 V) 2 Poles in Series, 40 °C 800 A (220 V) 3 Poles in Series, 40 °C 800 A (600 V) 3 Poles in Series, 40 °C 800 A (850 V) 3 Poles in Series, 40 °C 800 A
Rated Operational Current DC-3 (Ie)(110 V) 1-Pole, 40 °C 800 A (110 V) 2 Poles in Series, 40 °C 800 A (220 V) 3 Poles in Series, 40 °C 800 A (600 V) 3 Poles in Series, 40 °C 800 A
Rated Operational Current DC-5 (Ie)(110 V) 1-Pole, 40 °C 800 A (110 V) 2 Poles in Series, 40 °C 800 A (220 V) 3 Poles in Series, 40 °C 800 A (600 V) 3 Poles in Series, 40 °C 800 A
Rated Operational Power AC-3 (Pe)(415 V) 355 kW (440 V) 355 kW (500 V) 400 kW (690 V) 500 kW (1000 V) 355 kW (380 / 400 V) 315 kW (220 / 230 / 240 V) 160 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 1000 A
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 4500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 7000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 6400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 6000 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 5000 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour (AC-2 / AC-4) 60 cycles per hour (AC-3) 300 cycles per hour
Mechanical Durability3 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 36.5 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 36.5 V·A Holding at Max. Rated Control Circuit Voltage DC 4.1 V·A Holding at Max. Rated Control Circuit Voltage DC 4.1 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1000 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1000 V·A Pull-in at Max. Rated Control Circuit Voltage DC 1235 V·A Pull-in at Max. Rated Control Circuit Voltage DC 1235 W
Power Lossat Rated Operating Conditions AC-1 per Pole 39 W at Rated Operating Conditions AC-3 per Pole 21 W
Operate TimeBetween Coil De-energization and NC Contact Closing 50 ... 70 ms Between Coil De-energization and NO Contact Opening 53 ... 73 ms Between Coil Energization and NC Contact Opening 45 ... 115 ms Between Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main CircuitBar 52 mm² Bar 50 mm² Rigid Al-Cable 300 mm² Rigid Al-Cable 3x185 mm² Rigid Cu-Cable 300 mm² Rigid Cu-Cable 3x185 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 2x0.75 ... 2.5 mm² Solid 2 x 1 ... 4 mm² Stranded 1 x 1 .... 4 mm² Stranded 2 x 1 .... 4 mm²
Connecting CapacityBar 52 mm² Rigid Al-Cable 3x185 mm² Rigid Cu-Cable 3x185 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main PolesM 3.5 (+,-) pozidriv 2 screw with cable clamp
Recommended Screw DriverMain Circuit M12 Control Circuit Pozidriv 2 Control Circuit M3.5
Tightening TorqueCable Lug 45 N·m Main Circuit 45 N·m
Terminal TypeMain Circuit: Bars
Suitable for Product ClassBlock ContactorsBlock Contactors
Product NameBlock Contactor
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(1000 V AC) 750 A (600 V AC) 750 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 200 Hp (200 V AC) Three Phase 200 hp (208 V AC) Three Phase 200 hp (220 ... 240 V AC) Three Phase 250 Hp (220 ... 240 V AC) Three Phase 250 hp (440 ... 480 V AC) Three Phase 500 Hp (440 ... 480 V AC) Three Phase 500 hp (550 ... 600 V AC) Three Phase 600 Hp (550 ... 600 V AC) Three Phase 600 hp
Full Load Amps Motor Use(200 ... 208 V AC) Three Phase 552 A (220 ... 240 V AC) Three Phase 604 A (440 ... 480 V AC) Three Phase 590 A (550 ... 600 V AC) Three Phase 578 A
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C Operation -40 ... 70 °C Storage -40 ... +70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Shock Direction: A 5 g Shock Direction: B1 5 g Shock Direction: B2 5 g Shock Direction: C1 5 g Shock Direction: C2 5 g
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
ABB EcoSolutions Profile1SFC100125C0366
End Of Life Disassembling Instructions1SFC100112M0004
Environmental Product Declaration - EPD1SFC100109D0201 2TFP200025A1001
Extended Product LifetimeProduct Durability is Enhanced
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 69.7 %
ABS Certificate15-LD1408622-PDA
BV CertificateBV_13409-C0BV
CB CertificateSE-82863
CCS CertificateGB14T00030 GZ15T00069
CQC CertificateCQC2007010304256684 CQC2012010304540080
cULus CertificateUL_20111101-E36588
Declaration of Conformity - CE2CMT2019-005796
Declaration of Conformity - UKCA2CMT2020-006118
DNV CertificateTAE00001W1
LOVAG CertificateFI107
LR Certificate16-20064
PRS CertificateTE_2092_880423_16
RINA CertificateELE060313XG_002
UL Listing CardUL_E36588
Package Level 1 Unitsbox 1 piece
Package Level 1 Width280 mm
Package Level 1 Depth / Length375 mm
Package Level 1 Height310 mm
Package Level 1 Gross Weight15 kg
Package Level 1 EAN7320500217696
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
E-Number (Finland)3709334
E-Number (Norway)4115296
E-Number (Sweden)3228356

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.