AurFort
ABBAF1350-30-11-70ABB AF1350-30-11-70, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

POWER CONTACTOR, AC SWITCHING

AF1350-30-11-70

SKU 1SFL657001R7011

ABB AF1350-30-11-70: Power contactor, AC switching. Pole configuration: 3P.

3PPoles
AF1350-30-11-70Product range
Power contactor, AC switchingProduct type
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 08, 2026.

1SFL657001R7011 — selected manufacturer specifications
Product ID1SFL657001R7011
Catalog DescriptionAF1350-30-11 100-250V 50/60Hz / 100-250V DC Contactor
Country of OriginChina India
Lead Time28 day
Made To OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusInactive Active
Quote OnlyNo
Stocked At WarehousesINABB015EXPU
Minimum Order Quantity1 piece
Customs Tariff Number85364900
EPLAN Data9AAC200757_EPLAN
Data Sheet, Technical Information1SBC100214C0202
Data Sheet, Technical Information (Part 2)1SAC200017M0002
Instructions and Manuals1SFC101002M5501
CAD Dimensional Drawing2CDC001079B0201
Product Net Width438 mm
Product Net Depth / Length244 mm
Product Net Height392 mm
Product Net Weight32 kg
Dimension Diagram53540930-7
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles3P
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1350 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 1350 A (1000 V) 55 °C 1150 A (1000 V) 70 °C 1000 A (690 V) 40 °C 1350 A (690 V) 55 °C 1150 A (690 V) 70 °C 1000 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 860 A (440 V) 55 °C 860 A (500 V) 55 °C 800 A (690 V) 55 °C 800 A (1000 V) 55 °C 375 A (380 / 400 V) 55 °C 860 A (220 / 230 / 240 V) 55 °C 860 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 40 °C 1350 A (600 V) 3 Poles in Series, 40 °C 1350 A (850 V) 3 Poles in Series, 40 °C 1350 A
Rated Operational Current DC-3 (Ie)(220 V) 3 Poles in Series, 40 °C 1350 A (600 V) 3 Poles in Series, 40 °C 1350 A (850 V) 3 Poles in Series, 40 °C 1350 A
Rated Operational Current DC-5 (Ie)(220 V) 3 Poles in Series, 40 °C 1350 A (600 V) 3 Poles in Series, 40 °C 1350 A (850 V) 3 Poles in Series, 40 °C 1350 A
Rated Operational Power AC-3 (Pe)(415 V) 500 kW (440 V) 560 kW (500 V) 560 kW (690 V) 800 kW (1000 V) 560 kW (380 / 400 V) 475 kW (220 / 230 / 240 V) 257 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 8000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 10000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 6000 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 10000 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Maximum Electrical Switching Frequency(AC-1) 60 cycles per hour (AC-2 / AC-4) 60 cycles per hour (AC-3) 60 cycles per hour
Mechanical Durability0.5 million
Maximum Mechanical Switching Frequency60 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V 50 Hz / 60 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 75.7 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 75.7 V·A Holding at Max. Rated Control Circuit Voltage DC 14.1 V·A Holding at Max. Rated Control Circuit Voltage DC 14.1 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 2545 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 2545 V·A Pull-in at Max. Rated Control Circuit Voltage DC 2865 V·A Pull-in at Max. Rated Control Circuit Voltage DC 2865 W
Power Lossat Rated Operating Conditions AC-1 per Pole 66 W at Rated Operating Conditions AC-3 per Pole 27 W
Operate TimeBetween Coil De-energization and NC Contact Closing 35 ... 55 ms Between Coil De-energization and NO Contact Opening 35 ... 55 ms Between Coil Energization and NC Contact Opening 50 ... 80 ms Between Coil Energization and NO Contact Closing 50 ... 80 ms
Connecting Capacity Main CircuitBar 100 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm² Flexible with Ferrule 2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Flexible 2x0.75 ... 2.5 mm² Solid 2 x 1 ... 4 mm² Stranded 1 x 1 .... 4 mm² Stranded 2 x 1 .... 4 mm²
Connecting CapacityBar 100 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main PolesM 3.5 (+,-) pozidriv 2 screw with cable clamp
Recommended Screw DriverMain Circuit M12 Control Circuit Pozidriv 2 Control Circuit M3.5
Tightening TorqueCable Lug 45 N·m Main Circuit 45 N·m
Terminal TypeMain Circuit: Bars
Suitable for Product ClassBlock ContactorsBlock Contactors
Product NameBlock Contactor
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(1000 V AC) 1350 A (600 V AC) 1350 A
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 400 Hp (220 ... 240 V AC) Three Phase 400 hp (440 ... 480 V AC) Three Phase 800 Hp (440 ... 480 V AC) Three Phase 800 hp (550 ... 600 V AC) Three Phase 1000 Hp (550 ... 600 V AC) Three Phase 1000 hp
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 954 A (550 ... 600 V AC) Three Phase 944 A
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C Close to Contactor for Storage -40 ... 70 °C Operation -40 ... 70 °C Storage -40 ... +70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
ABB EcoSolutions Profile1SFC100125C0366
End Of Life Disassembling Instructions1SFC100112M0005
Environmental Product Declaration - EPD1SFC100110D0201 2TFP200026A1001
Extended Product LifetimeProduct Durability is Enhanced
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 71.3 %
ABS Certificate15-LD1408622-PDA
BV CertificateBV_13409-C0BV
CB CertificateSEMKO_SE-74013
CCS CertificateGB14T00030 GZ15T00069
CQC CertificateCQC2003010304101933 CQC2015010304752548
cULus CertificateUL_20130904-E73397 9AKK108469A9188
Declaration of Conformity - CE2CMT2019-005796
Declaration of Conformity - UKCA2CMT2020-006118
DNV CertificateTAE00001W1
LOVAG CertificateSE-202726
LR Certificate16-20064
PRS CertificateTE_2092_880423_16
RINA CertificateELE060313XG_002
UL Listing CardUL_E73397
Package Level 1 Unitsbox 1 piece
Package Level 1 Width555 mm
Package Level 1 Depth / Length365 mm
Package Level 1 Height500 mm
Package Level 1 Gross Weight34 kg
Package Level 1 EAN7320500250143
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
E-Number (Finland)3709257
E-Number (Norway)4115388
E-Number (Sweden)4115388

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.