AurFort
ABBCM-PVS.31SABB CM-PVS.31S, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

PHASE MONITORING RELAY

CM-PVS.31S

SKU 1SVR730794R1300

ABB CM-PVS.31S: Phase monitoring relay.

CM-PVS.31SProduct range
Phase monitoring relayProduct type
1SVR730794R1300Reference
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 09, 2026.

1SVR730794R1300 — selected manufacturer specifications
Product ID1SVR730794R1300
Catalog DescriptionCM-PVS.31S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x160-300VAC
Country of OriginIndia
Made To OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB015EXPU
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Data Sheet, Technical Information2CDC112211D0201
Instructions and Manuals1SVC730730M1000 1SVC730730M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132603_EPLAN
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.141 kg
FunctionPhase failure detection Phase sequence monitoring Over- and undervoltage monitoring
Measuring Range(L-L) 160 ... 300 V AC
Time RangeTripping Delay (ON or OFF) 0 s
Rated Control Supply Voltage (Us)(L-L) 160 ... 300 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output2 C/O Contacts
Terminal TypeScrew Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V 10 mA
Rated Impulse Withstand Voltage (Uimp)Input Circuit 6 kV Output Circuit 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 600 V Output Circuit 1 / Output Circuit 2 300 V
Degree of ProtectionHousing IP50 Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 1x 0.5 ... 2.5 mm² Flexible with Ferrule 2x 0.5 ... 1.5 mm² Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² Flexible 1x 0.5 ... 2.5 mm² Flexible 2x 0.5 ... 1.5 mm² Rigid 1x 0.5 ... 4 mm² Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque0.6 ... 0.8 N·m
Wire Stripping Length8 mm
Recommended Screw Driver0.8 x 4 4.5 Pozidriv 1
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14 IEC/EN 63000 IEC/EN 60255-27 IEC/EN 61000-6-2 IEC/EN 61000-6-3 UL 508
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 1x 18-14 AWG Flexible 2x 18-16 AWG Rigid 1x 20-12 AWG Rigid 2x 20-14 AWG
Tightening Torque UL/CSA7.08 in·lb
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Ambient Air TemperatureOperation -25 ... +60 °C Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutionsYes
ABB EcoSolutions Profile1SFC100125C0416
Environmental Product Declaration - EPD1SAC200438H0001
cULus CertificatecULus508_20120829-E140448
Declaration of Conformity - CCC2020980303000197
Declaration of Conformity - CE1SVD981014-00
DNV GL CertificateDNV_GL_TAA000017D
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.166 kg
Package Level 1 EAN4016779851831
E-Number (Finland)2712292
E-Number (Norway)4188153
E-Number (Sweden)3860583

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.