AurFort
ComPacT INSSchneider Electric switch-disconnector Compact INS400 - 400 A - 3 poles, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

SWITCH DISCONNECTOR

switch-disconnector Compact INS400 - 400 A - 3 poles

SKU 31110

Schneider Electric 31110 is a switch disconnector in the ComPacT INS range. Key specifications include operational current: AC-22A: 400 A AC 50/60 Hz 220/240 V; poles: 3P; operational voltage: 125 V DC.

AC-22A: 400 A AC 50/60 Hz 220/240 VOperational current
3PPoles
125 V DCOperational voltage
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 18, 2026.

31110 — selected manufacturer specifications
Product reference31110
RangeComPact
Product or component typeSwitch disconnector
Product nameComPacT INS
Poles description3P
Network typeAC DC
Network frequency50/60 Hz
[Ie] rated operational currentAC-22A: 400 A AC 50/60 Hz 220/240 V AC-22A: 400 A AC 50/60 Hz 380/415 V AC-22A: 400 A AC 50/60 Hz 440/480 V AC-22A: 400 A AC 50/60 Hz 480 V NEMA AC-22A: 400 A AC 50/60 Hz 500/525 V AC-22A: 400 A AC 50/60 Hz 660/690 V AC-23A: 400 A AC 50/60 Hz 220/240 V AC-23A: 400 A AC 50/60 Hz 380/415 V AC-23A: 400 A AC 50/60 Hz 440/480 V AC-23A: 400 A AC 50/60 Hz 480 V NEMA AC-23A: 400 A AC 50/60 Hz 500/525 V AC-23A: 400 A AC 50/60 Hz 660/690 V DC-22A: 400 A DC 125 V 2 poles in series DC-23A: 400 A DC 125 V 2 poles in series
[Ui] rated insulation voltage800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV 8 kV conforming to IEC 60947-3
[Ith] conventional free air thermal current400 A at 60 °C
[Icm] rated short-circuit making capacity330 kA with upstream protection circuit breaker 690 V AC at 50/60 Hz 50 kA switch-disconnector alone 690 V AC at 50/60 Hz
[Ue] rated operational voltage125 V DC 690 V AC 50/60 Hz
Suitability for isolationYes
Contact position indicatorYes
Visible breakNo
Pollution degree3
Control typeDirect front rotary handle
Handle colourBlack
Mounting modeFixed
Mounting supportPlate Rail
Upside connectionFront
Downside connectionFront
Maximum powerAC-23: 110 kW at 220/240 V AC 50/60 Hz AC-23: 110 kW at 230 V AC 50/60 Hz (NEMA) AC-23: 200 kW at 380/415 V AC 50/60 Hz AC-23: 220 kW at 440 V AC 50/60 Hz AC-23: 220 kW at 480 V AC 50/60 Hz (NEMA) AC-23: 250 kW at 500/525 V AC 50/60 Hz AC-23: 400 kW at 660/690 V AC 50/60 Hz
Rated dutyUninterrupted
[Icw] rated short-time withstand current11.5 kA during 3 s conforming to IEC 60947-3 20 kA during 1 s conforming to IEC 60947-3 4 kA during 30 s conforming to IEC 60947-3 4.9 kA during 20 s conforming to IEC 60947-3
Mechanical durability10000 cycles
Electrical durabilityAC-22A: 1500 cycles 440 V AC 50/60 Hz AC-22A: 1500 cycles 500 V AC 50/60 Hz AC-22A: 1500 cycles 690 V AC 50/60 Hz AC-23A: 1500 cycles 440 V AC 50/60 Hz AC-23A: 1500 cycles 500 V AC 50/60 Hz AC-23A: 1500 cycles 690 V AC 50/60 Hz DC-23A: 1000 cycles 125 V DC 2 poles in series
Connection pitch45 mm
Height205 mm
Width185 mm
Depth120 mm
Net weight4.6 kg
StandardsIEC 60947-1 IEC 60947-3
Product certificationsKEMA-KEUR CCC
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-50…85 °C

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.