AurFort
TeSys GCSchneider Electric TeSys GC - modular contactor - 16 A - 2 NO - coil 220...240 V AC, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

MODULAR CONTACTOR

TeSys GC - modular contactor - 16 A - 2 NO - coil 220...240 V AC

SKU GC1620M5

Schneider Electric GC1620M5 is a modular contactor in the TeSys GC range. Key specifications include operational current: 16 A AC-7A; control voltage: 220...240 V AC 50 Hz; poles: 2P.

16 A AC-7AOperational current
220...240 V AC 50 HzControl voltage
2PPoles
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 18, 2026.

GC1620M5 — selected manufacturer specifications
Product referenceGC1620M5
RangeTeSys
Product nameTeSys GC
Product or component typeModular contactor
Device short nameGC16
Contactor applicationHeating Motor control Lighting
Utilisation categoryAC-7A AC-7B
Poles description2P
power pole contact composition2 NO
[Ue] rated operational voltage<= 250 V AC
[Ie] rated operational current16 A AC-7A 5 A AC-7B
Operating position30°/vertical
Control circuit typeAC at 50 Hz
[Uc] control circuit voltage220...240 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kV
[Ith] conventional free air thermal current16 A (at 50 °C) for power circuit
Irms rated making capacity40 A at 400 V AC for power circuit conforming to IEC 61095
Rated breaking capacity40 A at 400 V for power circuit conforming to IEC 61095
[Icw] rated short-time withstand current128 A 40 °C - 10 s for power circuit 40 A 40 °C - 30 s for power circuit
Associated fuse rating16 A gL at <= 440 V for power circuit
Average impedance2.5 mOhm - Ith 16 A 50 Hz for power circuit
[Ui] rated insulation voltage500 V conforming to IEC 61095 500 V conforming to VDE 0110
Electrical durabilityAC-7A: 100000 cycles AC-7B: 100000 cycles
Power dissipation per pole0.65 W
Control typeRemote control
Mounting modeClip-on
Mounting supportDIN rail
StandardsIEC 61095 IEC 60947-5
Connections - terminalsControl circuit: screw clamp terminals 1 cable(s) 2.5 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 2.5 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 2.5 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1.5 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1.5 mm²solid without cable end Power circuit: screw clamp terminals 1 cable(s) 6 mm²flexible without cable end Power circuit: screw clamp terminals 2 cable(s) 4 mm²flexible without cable end Power circuit: screw clamp terminals 1 cable(s) 6 mm²flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end Power circuit: screw clamp terminals 1 cable(s) 6 mm²solid without cable end Power circuit: screw clamp terminals 2 cable(s) 4 mm²solid without cable end
Tightening torqueControl circuit: 0.8 N.m - on screw clamp terminals Power circuit: 0.8 N.m - on screw clamp terminals
Operating time10...25 ms opening 10...30 ms closing
Mechanical durability1000000 cycles
Maximum operating rate300 cyc/h 50 °C
Control circuit voltage limitsDrop-out: 0.2...0.75 Uc at 50 Hz (at <50 °C) Operational: 0.85...1.1 Uc at 50 Hz (at <50 °C)
Inrush power in VA15 VA 50 Hz (at 20 °C)
Hold-in power consumption in VA3.8 VA 50 Hz (at 20 °C)
Heat dissipation1.3 W at 50/60 Hz
IP degree of protectionIP40 conforming to VDE 0106 (in enclosure) IP20 conforming to VDE 0106
Protective treatmentTC
Ambient air temperature for operation-5…50 °C
Ambient air temperature for storage-40…70 °C
Operating altitude<= 3000 m
Mechanical robustnessShocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 3 Gn, 5...300 Hz
Total number of 18 mm modules1
Height81 mm
Width17.5 mm
Depth62.5 mm
Net weight0.11 kg
Quantity per setSet of 12
ColourWhite

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.