AurFort
TeSys GSchneider Electric Auxiliary contact block,TeSys Giga contactor,2NO,lateral face side mounting,push-in terminals L1/R1, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

AUXILIARY CONTACT BLOCK

Auxiliary contact block,TeSys Giga contactor,2NO,lateral face side mounting,push-in terminals L1/R1

SKU LAG8N203P

Schneider Electric LAG8N203P is a auxiliary contact block in the TeSys G range. Key specifications include contact configuration: 2 NO; operational voltage: 600 V AC 25...400 Hz; ip protection: IP20 conforming to IEC 60529.

2 NOContact configuration
600 V AC 25...400 HzOperational voltage
IP20 conforming to IEC 60529IP protection
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 06, 2026.

LAG8N203P — selected manufacturer specifications
Product referenceLAG8N203P
Range compatibilityTeSys G LC1G
Range of productTeSys G
RangeTeSys
Device short nameLAG8N
Product or component typeAuxiliary contact block
Auxiliary contacts operationInstantaneous
Pole contact composition2 NO
Connections - terminalsScrew clamp terminals0.75…2.5 mm²solid stranded without cable end Screw clamp terminals0.75…2.5 mm²flexible with cable end
Mounting locationSide
[Ui] rated insulation voltage600 V conforming to IEC 60947-5-1 600 V - certifications CSA 600 V - certifications UL
[Ue] rated operational voltage600 V AC 25...400 Hz
[Ith] conventional free air thermal current10 A (at 60 °C)
Irms rated making capacity140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1
Permissible short-time rating100 A 60 °C 1 s 120 A 60 °C 500 ms 140 A 60 °C 100 ms
Protection typeGG fuse 10 A
Mechanical durability8 Mcycles
Minimum switching current1 mA
Minimum switching voltage17 V
Non-overlap time1.5 ms on de-energisation no overlap between NC and NO contact 1.5 ms on energisation no overlap between NC and NO contact
Insulation resistance> 10 MOhm
Height55.8 mm
Width15.4 mm
Depth84.8 mm
Net weight0.05 kg
StandardsEN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB 14048.5 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ
Product certificationsCB Scheme CCC cULus CE UKCA
IP degree of protectionIP20 conforming to IEC 60529
Protective treatmentTH
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-60…80 °C
Operating altitude3000 m

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.