AurFort
TeSys GigaSchneider Electric High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 630A, standard version, 100…250V wide band AC/DC coil, manufacturer catalog image

Schneider Electric catalog image for this SKU; may represent the product family.

CONTACTOR

High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 630A, standard version, 100…250V wide band AC/DC coil

SKU LC1G630KUEN

Schneider Electric LC1G630KUEN is a contactor in the TeSys Giga range. Key specifications include operational current: 1050 A (at <40 °C) at <= 1000 V AC-1; contact configuration: 3 NO; control voltage: 100...250 V AC 50/60 Hz.

1050 A (at <40 °C) at <= 1000 V AC-1Operational current
3 NOContact configuration
100...250 V AC 50/60 HzControl voltage
PRODUCT DATA

Technical specifications

Source: Schneider Electric product catalog.
Verified September 06, 2026.

LC1G630KUEN — selected manufacturer specifications
Product referenceLC1G630KUEN
RangeTeSys
Range of productTeSys Giga
Product or component typeContactor
Device short nameLC1G
Contactor applicationPower switching Motor control
Utilisation categoryAC-1 AC-3 AC-3e AC-4 AC-5a AC-5b AC-6a AC-6b AC-8a AC-8b DC-1 DC-3 DC-5
Poles description3P
[Ue] rated operational voltage<= 1000 V AC 50/60 Hz <= 460 V DC
[Ie] rated operational current1050 A (at <40 °C) at <= 1000 V AC-1 630 A (at <60 °C) at <= 440 V AC-3
[Uc] control circuit voltage100...250 V AC 50/60 Hz 100...250 V DC
Control circuit voltage limitsOperational: 0.8 Uc Min...1.1 Uc Max (at <60 °C) Drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)
[Uimp] rated impulse withstand voltage8 kV
Overvoltage categoryIII
[Ith] conventional free air thermal current1050 A (at 40 °C)
Rated breaking capacity5550 A at 440 V
[Icw] rated short-time withstand current5.05 kA - 10 s 4.4 kA - 30 s 3.4 kA - 1 min 2.2 kA - 3 min 1.6 kA - 10 min
Associated fuse rating630 A aM at <= 440 V for motor 500 A aM at <= 690 V for motor 1250 A gG at <= 690 V 1000 A UL Type L at <= 600 V
Average impedance0.000065 Ohm
[Ui] rated insulation voltage1000 V
Power dissipation per pole70 W AC-1 - Ith 1050 A 26 W AC-3 - Ith 630 A
Compatibility codeLC1G
Pole contact composition3 NO
Auxiliary contact composition1 NO + 1 NC
Motor power kW180 kW at 230 V AC 50/60 Hz (AC-3e) 315 kW at 400 V AC 50/60 Hz (AC-3e) 335 kW at 415 V AC 50/60 Hz (AC-3e) 355 kW at 440 V AC 50/60 Hz (AC-3e) 375 kW at 500 V AC 50/60 Hz (AC-3e) 500 kW at 690 V AC 50/60 Hz (AC-3e) 450 kW at 1000 V AC 50/60 Hz (AC-3e) 200 kW at 230 V AC 50/60 Hz (AC-3) 335 kW at 400 V AC 50/60 Hz (AC-3) 375 kW at 415 V AC 50/60 Hz (AC-3) 400 kW at 440 V AC 50/60 Hz (AC-3) 400 kW at 500 V AC 50/60 Hz (AC-3) 500 kW at 690 V AC 50/60 Hz (AC-3) 450 kW at 1000 V AC 50/60 Hz (AC-3) 180 kW at 230 V AC 50/60 Hz (AC-4) 315 kW at 400 V AC 50/60 Hz (AC-4) 335 kW at 415 V AC 50/60 Hz (AC-4) 355 kW at 440 V AC 50/60 Hz (AC-4) 375 kW at 500 V AC 50/60 Hz (AC-4) 450 kW at 690 V AC 50/60 Hz (AC-4) 355 kW at 1000 V AC 50/60 Hz (AC-4)
Motor power hp250 hp at 200/208 V 60 Hz 300 hp at 230/240 V 60 Hz 600 hp at 460/480 V 60 Hz 700 hp at 575/600 V 60 Hz
Irms rated making capacity7220 A at 440 V
Coil technologyBuilt-in bidirectional peak limiting
Safety reliability levelB10d = 100000 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 1800000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability5 Mcycles
inrush power in VA (50/60 Hz, AC)800 VA
inrush power in W (DC)680 W
hold-in power consumption in VA (50/60 Hz, AC)15.0 VA
hold-in power consumption in W (DC)9.5 W
Operating time40...70 ms closing 15...50 ms opening
Maximum operating rate600 cyc/h AC-3 600 cyc/h AC-3e 300 cyc/h AC-1 150 cyc/h AC-4
Connections - terminalsPower circuit: bar 2 - busbar cross section: 52 x 20 mm Power circuit: lugs-ring terminals 1 185 mm² Power circuit: bolted connection Control circuit: push-in 1 0.2…2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 1 0.25…2.5 mm² - cable stiffness: flexible with cable end Control circuit: push-in 2 0.5…1.0 mm² with cable end Control circuit: push-in 0.75…2.5 mm² - cable stiffness: solid stranded without cable end Control circuit: push-in 0.75…2.5 mm² - cable stiffness: flexible with cable end
Connection pitch70 mm
Mounting supportPlate
StandardsEN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 JIS C8201-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-1 UL 60335-2-40:Annex JJ
Product certificationsCB Scheme CCC cULus EAC CE UKCA EU-RO-MR by DNV-GL
Tightening torque58 N.m
Height284 mm
Width211 mm
Depth266 mm
Net weight14.2 kg
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Ambient air temperature for operation-25…60 °C
Ambient air temperature for storage-60…80 °C
Mechanical robustnessVibrations 5…300 Hz 2 gn contactor open Vibrations 5…300 Hz 4 gn contactor closed Shocks 10 gn 11 ms contactor open Shocks 15 gn 11 ms contactor closed
ColourDark grey
Protective treatmentTH
Permissible ambient air temperature around the device-40…70 °C at Uc

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official Schneider Electric reference ↗.