AurFort
ABBNFZ31E-21ABB NFZ31E-21, manufacturer catalog image

ABB catalog image for this SKU; may represent the product family.

CONTACTOR RELAY

NFZ31E-21

SKU 1SBH136001R2131

ABB NFZ31E-21: Contactor relay. Pole configuration: 4P.

4PPoles
NFZ31E-21Product range
Contactor relayProduct type
PRODUCT DATA

Technical specifications

Source: ABB English regional product catalog.
Verified September 09, 2026.

1SBH136001R2131 — selected manufacturer specifications
Product ID1SBH136001R2131
Catalog DescriptionNFZ31E-21 24-60V50/60HZ 20-60VDC Contactor Relay
Country of OriginIndia
Made To OrderNo
Warranty ReturnProduct under warranty must be returned
Product Sales StatusActive
Quote OnlyNo
Stocked At WarehousesINABB015EXPU
Minimum Order Quantity1 piece
Customs Tariff Number85364900
EPLAN Data9AAC159655_EPLAN
Data Sheet, Technical Information1SBC100214C0202
Instructions and Manuals1SBC101027M6801
Instructions and Manuals (Part 2)1SAC200017M0002
CAD Dimensional Drawing2CDC001079B0201
Product Net Width45 mm
Product Net Depth / Length77 mm
Product Net Height86 mm
Product Net Weight0.31 kg
Number of Auxiliary Contacts NO3
Number of Auxiliary Contacts NC1
Number of Poles4P
StandardsIEC/EN 60947-1, IEC/EN 60947-5-1, UL 60335-2-40 LZGH2 A2L, UL 508, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 14-13
Rated Operational VoltageAuxiliary Circuit 690 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W
Rated Short-time Withstand Current Low Voltage (Icw)for 0.1 s 140 A for 1 s 100 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-5-1 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Electrical Switching Frequency(AC-15) 1200 cycles per hour (DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency6000 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V
Power Lossat 6 A per Pole 0.1 W
Operate TimeBetween Coil De-energization and NC Contact Closing 13 ... 98 ms Between Coil De-energization and NO Contact Opening 11 ... 95 ms Between Coil Energization and NC Contact Opening 38 ... 90 ms Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)2 x M4 Screws Placed Diagonally
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm Control Circuit 10 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Tightening TorqueAuxiliary Circuit 1.2 N·m Control Circuit 1.2 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor Relay
Connecting Capacity Auxiliary Circuit UL/CSARigid Solid 1/2x 18-14 AWG Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb Control Circuit 11 in·lb
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: B1 25 g Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g Shock Direction: C2 25 g
Resistance to Vibrations4g Closed Position & 2g Open position 5 ... 300 Hz
Pollution Degree3
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Simplified SCIP08974f12-1934-4d11-9d06-558e7fff9a30 Belgium 14b8c9c6-ab9f-4bc4-83cb-957bf6487f53 Estonia 269d4840-79b6-47ff-bb5d-8c865f7e304a Portugal 38178fa6-36b8-4ef8-8365-43e4d52872f5 Germany 389f4bd8-d7e5-4089-9a8b-a661b80134f3 Germany 3c484d5b-bb06-4dd8-89fc-d4f0d507ef20 Hungary 47e2d89e-36cb-4bda-92e7-1f03d07d3e21 Spain 5f157260-94a0-4ac0-9f6e-ac7499350e65 Poland 65f76813-1abb-4708-ac21-a4429def1e29 France 7864a4be-3f73-461c-b346-cbe84ba49043 France 7ed5f58a-716f-4cfb-91f4-abfaa1c42b38 Germany 8400cbd9-7d19-4be3-86f0-d03db8b6b691 Croatia 9212b478-2e81-4a4b-a7f3-763db51c95a5 Netherlands 9286fd43-f525-4618-bef0-c49a1d5f105f Poland 97c01a9b-4432-40a1-bfbd-63bed0954929 Belgium 9924608d-263c-44f4-a4d5-4c9a221ad138 Czechia a9ce4914-7429-42c1-8144-93378bf942af Germany a9f4addb-b83c-4ed1-b69b-526f4c8d25f9 Greece ab3773ce-d5ab-411f-9316-2cd4fa7bf7fc Poland b0eac2ca-6b15-494c-aa1e-f900638b1119 Hungary b510274e-0650-4007-ab74-9371439ba03e Germany c0010270-3d04-403b-a2cf-70f8ffcd6d48 Bulgaria cd2d10fe-52a4-4526-b415-69e0ff24fb0e Sweden d47bc716-0967-4bfa-807d-723a0367444d Denmark e588da92-3c39-4c7c-a149-65bbeb4ab6c3 Sweden f046ec7d-97f7-4f40-96e3-c6b1f9fbafaa Finland f82392db-ee81-4c3b-8582-38ac27912e02 Norway
Toxic Substances Control Act - TSCA2CMT2023-006525
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
ABB EcoSolutions Profile1SBC100156C0308
End Of Life Disassembling Instructions1SBC101080M6801
Environmental Product Declaration - EPD1SBD250584E3000
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 92.7 %
A2L Certificate – UL9AKK108469A4900 9AKK108469A4902
ABS CertificateABS_26-0348269-PDA_FR ABS_26-0348269-PDA-DUP_CN
BV CertificateBV_2634H24899C1
CB CertificateCB_SE-117902
CCC CertificateCCC_2024010303656666
Declaration of Conformity - CCCCQC2011010303465426
Declaration of Conformity - CE1SBD250005U1000
Declaration of Conformity - UKCA1SBD250036U1000
DNV CertificateDNV_TAE00001BV-6
LR CertificateLRS_LR2003684TA-02
RINA CertificateRINA_ELE142224XG
RMRS CertificateRMRS_1802702280
UL CertificateUL_20180227_E252354_2_1
UL Listing CardUL_E252354
Package Level 1 Unitsbox 1 piece
Package Level 1 Width87 mm
Package Level 1 Depth / Length79 mm
Package Level 1 Height47 mm
Package Level 1 Gross Weight0.31 kg
Package Level 1 EAN3471523101814
IDEA Granular Category Code (IGCC)4763 >> Power contactor, DC switching
E-Number (Finland)3706411
E-Number (Sweden)3211450

For complete electrical ratings, applicable standards, connection requirements and installation instructions, consult the official ABB reference ↗.